Literature DB >> 14727750

Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.

Emily Heath1, Jan Seuntjens.   

Abstract

A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of leaf sequence files to simulate the movement of the multileaf collimator (MLC) leaves during an intensity modulated radiation therapy (IMRT) delivery. As an initial validation of the code, the individual leaf geometries were visualized by tracing particles through the component module and recording their position each time a leaf boundary was crossed. A model of the Varian CL21EX linear accelerator 6 MV photon beam incorporating the new CM was built with the BEAMnrc user code. The leaf material density and abutting leaf air gap were chosen to match simulated leaf leakage profiles with film measurements in a solid water phantom. Simulated depth dose and off-axis profiles for a variety of MLC defined static fields agreed to within 2% with ion chamber and diode measurements in a water phantom. Simulated dose distributions for IMRT intensity patterns delivered using both static and dynamic techniques were found to agree with film measurements to within 4%. A comparison of interleaf leakage profiles for the new CM and an equivalent leaf model using the existing VARMLC CM demonstrated that the simplified geometry of VARMLC is not able to accurately predict the details of the MLC leakage for the 120 leaf collimator.

Entities:  

Mesh:

Year:  2003        PMID: 14727750     DOI: 10.1088/0031-9155/48/24/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4.

Authors:  Hiroyuki Okamoto; Yukio Fujita; Kyoko Sakama; Hidetoshi Saitoh; Tatsuaki Kanai; Jun Itami; Toshiyuki Kohno
Journal:  Radiol Phys Technol       Date:  2014-02-08

2.  Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.

Authors:  Shingo Ohira; Hideki Takegawa; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

3.  Performance Evaluation of Algorithms in Lung IMRT: A comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms.

Authors:  T Verma; N K Painuly; S P Mishra; M Shajahan; N Singh; M L B Bhatt; N Jamal; M C Pant
Journal:  J Biomed Phys Eng       Date:  2016-09-01

4.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

5.  Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems.

Authors:  Sanaz Hariri; Majid Shahriari
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

6.  Development of a dose verification system for Vero4DRT using Monte Carlo method.

Authors:  Yoshitomo Ishihara; Akira Sawada; Mitsuhiro Nakamura; Yuki Miyabe; Hiroaki Tanabe; Shuji Kaneko; Kenji Takayama; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

7.  Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

Authors:  Alanah M Bergman; Ermias Gete; Cheryl Duzenli; Tony Teke
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.