Literature DB >> 14726054

Hemodynamic unloading of the failing left ventricle using an arterial-to-arterial extracorporeal flow circuit.

Benjamin E Haithcock1, Hideaki Morita, Nervin H Fanous, George Suzuki, Hani N Sabbah.   

Abstract

We tested the hypothesis that creation of a constant-flow extracorporeal circuit between the proximal and distal aorta will unload the failing left ventricle. Studies were performed in 14 heart failure dogs produced by intracoronary microembolizations. An extracorporeal circuit incorporating a diagonal pump was placed between a femoral and a carotid artery, with flow directed to the carotid. Hemodynamic measurements were made with the pump delivering 0.25 L/min through the circuit for 4 hours (active group). Measurements obtained from 8 sham-operated heart failure dogs were used for comparison (control group). Heart rate, peak left ventricular systolic pressure, left ventricular end-diastolic pressure, end-diastolic volume, end-systolic volume, and ejection fraction were measured at baseline and at 30, 60, 120, and 240 minutes. There were no differences in any of the hemodynamic values during the 4 hours of follow-up in the control group. In the active group, there was no effect on heart rate or peak systolic pressure, but reductions between baseline and 240 minutes were observed in left ventricular end-diastolic pressure (15 +/- 1 vs 6 +/- 1 mm Hg, p < 0.05), end-diastolic volume (61 +/- 3 vs 50 +/- 3 mL, p < 0.05), and end-systolic volume (44 +/- 2 vs 32 +/- 2 mL, p < 0.05), and an increase in ejection fraction (28 +/- 2 vs 37% +/- 2%, p < 0.05). Acute use of this artery-to-artery extracorporeal system effectively unloads the failing left ventricle. The potential benefits of this approach on long-term myocardial recovery in heart failure require further investigation.

Entities:  

Mesh:

Year:  2004        PMID: 14726054     DOI: 10.1016/s0003-4975(03)01199-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

Review 1.  Percutaneous mechanical devices in the management of decompensated heart failure.

Authors:  Paul J Mather; Marvin A Konstam
Journal:  Curr Heart Fail Rep       Date:  2007-03

Review 2.  Mechanical support in acute and chronic heart failure.

Authors:  Andreas Brieke; Joseph Cleveland; JoAnn Lindenfeld
Journal:  Curr Cardiol Rep       Date:  2008-05       Impact factor: 2.931

3.  Neurohumoral response and clinical effectiveness of continuous aortic flow augmentation in patients with decompensated heart failure.

Authors:  Till Neumann; Georg Aidonides; Thomas Konorza; Peter Krings; Raimund Erbel
Journal:  J Artif Organs       Date:  2009-09-19       Impact factor: 1.731

Review 4.  Large animal models of heart failure: a critical link in the translation of basic science to clinical practice.

Authors:  Jennifer A Dixon; Francis G Spinale
Journal:  Circ Heart Fail       Date:  2009-05       Impact factor: 8.790

5.  Theoretical estimation of cannulation methods for left ventricular assist device support as a bridge to recovery.

Authors:  Ki Moo Lim; Jeong Sang Lee; Jin-Ho Song; Chan-Hyun Youn; Jae-Sung Choi; Eun Bo Shim
Journal:  J Korean Med Sci       Date:  2011-11-29       Impact factor: 2.153

Review 6.  Newer mechanical devices in the management of acute heart failure.

Authors:  Paul J Mather; Marvin A Konstam
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.654