Literature DB >> 1472169

Continuous monitoring of jugular venous oxygen saturation in head-injured patients.

M Sheinberg1, M J Kanter, C S Robertson, C F Contant, R K Narayan, R G Grossman.   

Abstract

The continuous measurement of jugular venous oxygen saturation (SjvO2) with a fiberoptic catheter is evaluated as a method of detecting cerebral ischemia after head injury. Forty-five patients admitted to the hospital in coma after severe head injury had continuous and simultaneous monitoring of SjvO2, intracranial pressure, arterial oxygen saturation, and end-tidal CO2. Cerebral blood flow, cerebral metabolic rates of oxygen and lactate, arterial and jugular venous blood gas levels, and hemoglobin concentration were measured every 8 hours for 1 to 11 days. Whenever SjvO2 dropped to less than 50%, a standardized protocol was followed to confirm the validity of the desaturation and to establish its cause. Correlation of SjvO2 values obtained by catheter and with direct measurement of O2 saturation by a co-oximeter on venous blood withdrawn through the catheter was excellent after in vivo calibration when there was adequate light intensity at the catheter tip (176 measurements: r = 0.87, p less than 0.01). A total of 60 episodes of jugular venous oxygen desaturation occurred in 45 patients. In 20 patients the desaturation value was confirmed by the co-oximeter. There were 33 episodes of desaturation in these 20 patients, due to the following causes: intracranial hypertension in 12 episodes, hypocarbia in 10, arterial hypoxia in six, combinations of the above in three, systemic hypotension in one, and cerebral vasospasm in one. The incidence of jugular venous oxygen desaturations found in this study suggests that continuous monitoring of SjvO2 may be of clinical value in patients with head injury.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1472169     DOI: 10.3171/jns.1992.76.2.0212

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  35 in total

1.  [Continuous measurement of jugular venous blood gas. A case of subarachnoid bleeding].

Authors:  M Menzel; J Soukup; A Rieger; S Roth; J Radke; W Burkert
Journal:  Anaesthesist       Date:  1997-04       Impact factor: 1.041

2.  Lower limits of hematocrit and mixed venous oxygen saturation ensuring sufficient cerebral oxygenation during hemodilution in rabbits.

Authors:  Koji Ogata; Hidenori Inoue; Shinpei Yoshii; Syunya Shindo; Hiroji Higuchi; Hiroshi Osawa; Okihiko Akashi; Eiki Mizutani; Yoshimitsu Hiejima; Masahiko Matsumoto
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2006-02

3.  Secondary insults during intrahospital transport of neurosurgical intensive care patients.

Authors:  A Bekar; Z Ipekoglu; K Türeyen; H Bilgin; G Korfali; E Korfali
Journal:  Neurosurg Rev       Date:  1998       Impact factor: 3.042

4.  Evaluation of a regional oxygen saturation catheter for monitoring SjvO2 in head injured patients.

Authors:  A M Ritter; S P Gopinath; C Contant; R K Narayan; C S Robertson
Journal:  J Clin Monit       Date:  1996-07

5.  Cerebral blood flow and metabolism in children with severe head injury. Part 1: Relation to age, Glasgow coma score, outcome, intracranial pressure, and time after injury.

Authors:  P M Sharples; A G Stuart; D S Matthews; A Aynsley-Green; J A Eyre
Journal:  J Neurol Neurosurg Psychiatry       Date:  1995-02       Impact factor: 10.154

6.  Cerebral blood flow and metabolism in children with severe head injuries. Part 2: Cerebrovascular resistance and its determinants.

Authors:  P M Sharples; D S Matthews; J A Eyre
Journal:  J Neurol Neurosurg Psychiatry       Date:  1995-02       Impact factor: 10.154

Review 7.  Physiological monitoring of the severe traumatic brain injury patient in the intensive care unit.

Authors:  Peter Le Roux
Journal:  Curr Neurol Neurosci Rep       Date:  2013-03       Impact factor: 5.081

8.  Early jugular bulb oxygenation monitoring in comatose patients after an out-of-hospital cardiac arrest.

Authors:  J G van der Hoeven; J de Koning; E A Compier; A E Meinders
Journal:  Intensive Care Med       Date:  1995-07       Impact factor: 17.440

9.  Estimation of jugular venous O2 saturation from cerebral oximetry or arterial O2 saturation during isocapnic hypoxia.

Authors:  M B Kim; D S Ward; C R Cartwright; J Kolano; S Chlebowski; L C Henson
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

10.  Comparison of local measurement of cerebral metabolism and to cerebral PvO2 during alterations in intracranial pressure, PaCO2 and arterial pressure--an experimental study in goat.

Authors:  Aram Ter Minassian; Jean Claude Desfontis; Freddy Gautier; Claire Douart; Mauro Ursino; Benoît Denizot; Marc Gogny; Laurent Beydon
Journal:  J Clin Monit Comput       Date:  2002-12       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.