Influence of high-pass filtering on noncontact mapping and ablation of atrial tachycardias.

Michael A E Schneider1, Gjin Ndrepepa, Stefan Weber, Isabel Deisenhofer, Albert Schömig, Claus Schmitt.   

Abstract

The aim of the study was to define the impact of different high-pass filter settings (HPF) on the accuracy of mapping of ectopic atrial tachycardias (EAT) using a noncontact mapping (NCM) system. In 20 patients with 22 EAT a noncontact probe was deployed in the right (n = 19) or in the left atrium (n = 3). The device enables interpolation and analysis of unipolar electrograms. It provides information on focus localization and signal morphology. These parameters were compared in different HPF of 0.5 Hz, 2 Hz, 8 Hz, and 16 Hz. The NCM signal morphology was preserved at all HPF. An initial negative deflection recorded by NCM system showed a positive predictive value of 93% regarding the ablation success. The deviation (spatial disparity) between visualized focus origin and successful ablation site was 6.9 +/- 5.4 mm. Between two consecutive filter settings, the focus shift was more pronounced between 0.5 and 2 Hz (5.4 +/- 4.5 mm) compared to a setting between 8 and 16 Hz (2.9 +/- 2.9 mm; P < 0.05). Successful ablation was achieved in 15/18 right atrial tachycardias (83%) and in 2/3 left atrial arrhythmias. Different HPF influence NCM spatial analysis of EAT. However, a small variability in foci localization does not impact final ablation results.

Entities:  

Mesh:

Year:  2004        PMID: 14720153     DOI: 10.1111/j.1540-8159.2004.00383.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Can noncontact mapping distinguish between endo- and epicardial foci?

Authors:  Frederik Voss; Alexander Bauer; Steffen Witte; Hugo A Katus; Ruediger Becker
Journal:  Clin Res Cardiol       Date:  2008-05-03       Impact factor: 5.460

Review 2.  A Review of Healthy and Fibrotic Myocardium Microstructure Modeling and Corresponding Intracardiac Electrograms.

Authors:  Jorge Sánchez; Axel Loewe
Journal:  Front Physiol       Date:  2022-05-10       Impact factor: 4.755

3.  The Impact of Filter Settings on Morphology of Unipolar Fibrillation Potentials.

Authors:  Roeliene Starreveld; Paul Knops; Maarten Roos-Serote; Charles Kik; Ad J J C Bogers; Bianca J J M Brundel; Natasja M S de Groot
Journal:  J Cardiovasc Transl Res       Date:  2020-05-14       Impact factor: 4.132

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.