Literature DB >> 14719897

Analysis in ultrasmall volumes: microdispensing of picoliter droplets and analysis without protection from evaporation.

Sebastian Neugebauer1, Stephanie R Evans, Zoraida P Aguilar, Marcus Mosbach, Ingrid Fritsch, Wolfgang Schuhmann.   

Abstract

A new approach is reported for analysis of ultrasmall volumes. It takes advantage of the versatile positioning of a dispenser to shoot approximately 150-pL droplets of liquid onto a specific location of a substrate where analysis is performed rapidly, in a fraction of the time that it takes for the droplet to evaporate. In this report, the site where the liquid is dispensed carries out fast-scan cyclic voltammetry (FSCV), although the detection method does not need to be restricted to electrochemistry. The FSCV is performed at a microcavity having individually addressable gold electrodes, where one serves as working electrode and another as counter/pseudoreference electrode. Five or six droplets of 10 mM [Ru(NH(3))(6)]Cl(3) in 0.1 M KCl were dispensed and allowed to dry, followed by redissolution of the redox species and electrolyte with one or five droplets of water and immediate FSCV, demonstrating the ability to easily concentrate a sample and the reproducibility of redissolution, respectively. Because this approach does not integrate detection with microfluidics on the same chip, it simplifies fabrication of devices for analysis of ultrasmall volumes. It may be useful for single-step and multistep sample preparation, analyses, and bioassays in microarray formats if dispensing and changing of solutions are automated. However, care must be taken to avoid factors that affect the aim of the dispenser, such as drafts and clogging of the nozzle.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14719897     DOI: 10.1021/ac0346860

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Electrochemical attosyringe.

Authors:  François O Laforge; James Carpino; Susan A Rotenberg; Michael V Mirkin
Journal:  Proc Natl Acad Sci U S A       Date:  2007-07-09       Impact factor: 11.205

2.  Evaporation from microreservoirs.

Authors:  N Scott Lynn; Charles S Henry; David S Dandy
Journal:  Lab Chip       Date:  2009-03-16       Impact factor: 6.799

Review 3.  Managing evaporation for more robust microscale assays. Part 1. Volume loss in high throughput assays.

Authors:  Erwin Berthier; Jay Warrick; Hongmeiy Yu; David J Beebe
Journal:  Lab Chip       Date:  2008-04-08       Impact factor: 6.799

4.  A microfabricated nanocalorimeter: design, characterization, and chemical calibration.

Authors:  Junkai Xu; Ron Reiserer; Joel Tellinghuisen; John P Wikswo; Franz J Baudenbacher
Journal:  Anal Chem       Date:  2008-03-20       Impact factor: 6.986

5.  Arbitrarily Accessible 3D Microfluidic Device for Combinatorial High-Throughput Drug Screening.

Authors:  Zhuofa Chen; Weizhi Li; Gihoon Choi; Xiaonan Yang; Jun Miao; Liwang Cui; Weihua Guan
Journal:  Sensors (Basel)       Date:  2016-09-29       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.