Literature DB >> 14717715

Ambulatory pulse pressure, left ventricular hypertrophy and function in arterial hypertension.

Vito Rizzo1, Fernando di Maio, Federica Petretto, Marta Marziali, Gianluca Bianco, Francesco Barilla, Vincenzo Paravati, Daniele Pignata, Stefano Villatico Campbell, Giuseppe Donato, Vincenzo Bernardo, Demetrio Tallarico.   

Abstract

BACKGROUND: A wide pulse pressure (PP) can provide important risk assessment information about myocardial infarction, carotid artery atherosclerosis, and global cardiovascular risk. Ambulatory pulse pressure (APP) does not have a well-known prognostic value in hypertensive patients.
METHODS: To evaluate the relationship among high APP, atrial volumes, and cardiac function, an observational study was performed on 108 untreated non-elderly hypertensive patients (mean age 54.23 +/- 7.12). Twenty-four-hour ambulatory blood pressure monitoring, Doppler and echocardiographic measurements of systolic, diastolic function, left and right atrial volumes, left ventricular mass index and dimensions, were performed in subjects with both clinic and APP > 60 mmHg (APP1 Group). A control group of hypertensive selected subjects with both clinic and APP < 60 mmHg was chosen (APP 2 Group).
RESULTS: The APP1 group showed left atrial volume enlargement, high left ventricular mass index, and impaired diastolic function. A positive correlation was found in the APP1 group results among left ventricular end diastolic diameter (r = 0.39, P < 0.01), left atrial volume (0.38, P < 0.05), and left ventricular mass index (r = 0.33, P < 0.05); clinic PP showed a statistically significant correlation with left atrial volume, left ventricular end diastolic diameter, and left ventricular mass index only in the APP1 group.
CONCLUSIONS: These results suggest that elevated APP can be considered an effective predictor of cardiovascular risk in hypertensive subjects. In these patients echocardiographic evaluation of left ventricular function and morphology can increase the prognostic value of PP.

Entities:  

Mesh:

Year:  2004        PMID: 14717715     DOI: 10.1111/j.0742-2822.2004.02146.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  1 in total

1.  Pulse pressure findings following upper cervical care: a practice-based observational study.

Authors:  Robert Kessinger; Trevor Qualls; John Hart; Henri Dallies; Michael Anderson; Jered Wayland; Leldon Bradshaw
Journal:  J Can Chiropr Assoc       Date:  2019-04
  1 in total