Efforts to improve cementless femoral stems in THR: 2- to 5-year follow-up of a high-offset femoral stem with distal stem modification (Secur-Fit Plus).

Stephen J Incavo1, Todd Havener, Eric Benson, Brian J McGrory, Kathryn M Coughlin, Bruce D Beynnon.   

Abstract

A retrospective review of 81 sequential primary total hip arthroplasties using a cementless, high-offset femoral stem was performed. Follow-up was 24 to 60 months. The average age at the time of surgery was 54 years. The femoral bone types were: 36% Dorr A, 51% Dorr B, and 13% Dorr C. The mean postoperative Harris Hip Score was 95. The mean postoperative Oxford score was 17. Eighty-five percent had no clinical leg-length difference. All stems were radiographically stable. The stem features of hydroxyapatite coating on a rough circumferential titanium arc-deposit proximal surface in conjunction with distal flutes seem to provide immediate stability, making this implant clinically versatile. Potential benefits of increased offset include improved joint stability and avoidance of leg lengthening.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14716653     DOI: 10.1016/j.arth.2003.09.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

1.  Implant positioning in total hip arthroplasty: influence of horizontal and vertical offset on functionality of prosthetic hip joint.

Authors:  Arun Vaishy; Mohd Arif; Rahul Aanand; Kamaldeep Singh; Hitesh Kumar Rulaniya; Naveen Kumawat; Ramakishan Choudhary; Paras Choudhary
Journal:  Int Orthop       Date:  2022-03-15       Impact factor: 3.479

2.  Morbid obesity may increase dislocation in total hip patients: a biomechanical analysis.

Authors:  Jacob M Elkins; Matej Daniel; Douglas R Pedersen; Bhupinder Singh; H John Yack; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2012-08-21       Impact factor: 4.176

3.  The influence of stem offset and neck shaft angles on the range of motion in total hip arthroplasty.

Authors:  Takeshi Shoji; Takuma Yamasaki; Soutarou Izumi; Susumu Hachisuka; Mitsuo Ochi
Journal:  Int Orthop       Date:  2015-07-30       Impact factor: 3.075

4.  Lateral trochanteric pain following total hip arthroplasty: radiographic assessment of altered biomechanics as a potential aetiology.

Authors:  Ali Abdulkarim; Cathy Keegan; Raazi Bajwa; Eoin Sheehan
Journal:  Ir J Med Sci       Date:  2018-01-15       Impact factor: 1.568

5.  Can a Conical Implant Successfully Address Complex Anatomy in Primary THA? Radiographs and Hip Scores at Early Followup.

Authors:  Quoqiang Zhang; Stuart B Goodman; William J Maloney; James I Huddleston
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

6.  Changes in femoral offset is not associated with increased incidence of lateral hip pain following total hip arthroplasty.

Authors:  Michael Foy; Daniel Kielminski; Daniel Cavazos; Awais Hussain; Anshum Sood; Mark Gonzalez
Journal:  J Clin Orthop Trauma       Date:  2020-12-10

7.  Trochanteric impingement: is it a source of pain after THR?

Authors:  Mark J Isaacson; Kevin J Bunn; Stephen J Incavo
Journal:  Arthroplast Today       Date:  2015-09-04

8.  Intellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty.

Authors:  Wayne G Paprosky; Jeffrey M Muir
Journal:  Med Devices (Auckl)       Date:  2016-11-18

9.  5-year clinical and radiographic follow-up of the uncemented Symax hip stem in an international study.

Authors:  Dennis Silvester Maria Gerardus Kruijntjens; Per Kjaersgaard-Andersen; Peter Revald; Jane Schwartz Leonhardt; Jacobus Johannes Chris Arts; René Hendrikus Maria Ten Broeke
Journal:  J Orthop Surg Res       Date:  2018-07-31       Impact factor: 2.359

10.  Does Proximally Coated Single-Wedge Cementless Stem Work Well in Dorr Type C Femurs? Minimum 10-year Followup.

Authors:  Jung-Taek Kim; Hyung Jun Jeong; Soong Joon Lee; Hee Joong Kim; Jeong Joon Yoo
Journal:  Indian J Orthop       Date:  2019 Jan-Feb       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.