Literature DB >> 14715073

Effect of target biological tissue and choice of light source on penetration depth and resolution in optical coherence tomography.

Ann W Sainter1, Terry A King, Mark R Dickinson.   

Abstract

The effectiveness of an optical coherence tomography (OCT) system depends largely on the light source chosen. Published data on the optical properties of tissues are used to quantify the exponential attenuation of broadband light on transport through tissue. The effective attenuation coefficient is taken to be the sum of the absorption and scattering coefficients. This is used to demonstrate the effect on the spectra of a wide range of published OCT sources and the change in system resolution induced, and hence to comment on the suitability of different sources for OCT. The tissues studied include skin dermis, liver, and gallbladder. Sources at higher wavelengths are shown to be capable of high-resolution OCT imaging at greater depths. Titanium:sapphire lasers would be most suited for high-resolution OCT over comparatively shallow depths into tissue. For lower-resolution applications of OCT, a semiconductor optical amplifier and ytterbium fiber sources have better powers and bandwidths than superluminescent diodes. The resolution of OCT systems is not reduced significantly with imaging depth. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Mesh:

Year:  2004        PMID: 14715073     DOI: 10.1117/1.1628243

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  8 in total

Review 1.  Review of the progress toward achieving heat confinement-the holy grail of photothermal therapy.

Authors:  Wangzhong Sheng; Sha He; William J Seare; Adah Almutairi
Journal:  J Biomed Opt       Date:  2017-08-01       Impact factor: 3.170

2.  Thermal therapy with magnetic nanoparticles for cell destruction.

Authors:  Adi Vegerhof; Menachem Motei; Arkady Rudinzky; Dror Malka; Rachela Popovtzer; Zeev Zalevsky
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

3.  Imaging deep skeletal muscle structure using a high-sensitivity ultrathin side-viewing optical coherence tomography needle probe.

Authors:  Xiaojie Yang; Dirk Lorenser; Robert A McLaughlin; Rodney W Kirk; Matthew Edmond; M Cather Simpson; Miranda D Grounds; David D Sampson
Journal:  Biomed Opt Express       Date:  2013-12-10       Impact factor: 3.732

Review 4.  Intraoperative imaging in pathology-assisted surgery.

Authors:  Floris J Voskuil; Jasper Vonk; Bert van der Vegt; Schelto Kruijff; Vasilis Ntziachristos; Pieter J van der Zaag; Max J H Witjes; Gooitzen M van Dam
Journal:  Nat Biomed Eng       Date:  2021-11-08       Impact factor: 25.671

Review 5.  Targeting drug delivery with light: A highly focused approach.

Authors:  Teresa L Rapp; Cole A DeForest
Journal:  Adv Drug Deliv Rev       Date:  2021-01-22       Impact factor: 15.470

6.  Investigation of the impact of water absorption on retinal OCT imaging in the 1060 nm range.

Authors:  Sebastian Marschall; Christian Pedersen; Peter E Andersen
Journal:  Biomed Opt Express       Date:  2012-06-18       Impact factor: 3.732

7.  Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm.

Authors:  V M Kodach; J Kalkman; D J Faber; T G van Leeuwen
Journal:  Biomed Opt Express       Date:  2010-07-16       Impact factor: 3.732

Review 8.  Evaluation of Choroidal Thickness Using Optical Coherent Tomography: A Review.

Authors:  Rui Xie; Bingjie Qiu; Jay Chhablani; Xinyuan Zhang
Journal:  Front Med (Lausanne)       Date:  2021-12-03
  8 in total