Literature DB >> 14713088

An alternative derivation of Katsevich's cone-beam reconstruction formula.

Guang-Hong Chen1.   

Abstract

In this paper an alternative derivation of Katsevich's cone-beam image reconstruction algorithm is presented. The starting point is the classical Tuy's inversion formula. After (i) using the hidden symmetries of the intermediate functions, (ii) handling the redundant data by weighting them, (iii) changing the weighted average into an integral over the source trajectory parameter, and (iv) imposing an additional constraint on the weighting function, a filtered backprojection reconstruction formula from cone beam projections is derived. The following features are emphasized in the present paper: First, the nontangential condition in Tuy's original data sufficiency conditions has been relaxed. Second, a practical regularization scheme to handle the singularity is proposed. Third, the derivation in the cone beam case is in the same fashion as that in the fan-beam case. Our final cone-beam reconstruction formula is the same as the one discovered by Katsevich in his most recent paper. However, the data sufficiency conditions and the regularization scheme of singularities are different. A detailed comparison between these two methods is presented.

Entities:  

Mesh:

Year:  2003        PMID: 14713088     DOI: 10.1118/1.1628413

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  A filtered backprojection algorithm for triple-source helical cone-beam CT.

Authors:  Jun Zhao; Yannan Jin; Yang Lu; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2009-03       Impact factor: 10.048

2.  Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory.

Authors:  Tingliang Zhuang; Joseph Zambelli; Brian Nett; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

Review 3.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 4.  The meaning of interior tomography.

Authors:  Ge Wang; Hengyong Yu
Journal:  Phys Med Biol       Date:  2013-08-02       Impact factor: 3.609

5.  Cone-Beam CT with a Flat-Panel Detector: From Image Science to Image-Guided Surgery.

Authors:  Jeffrey H Siewerdsen
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-08-21       Impact factor: 1.455

6.  Tensor framelet based iterative image reconstruction algorithm for low-dose multislice helical CT.

Authors:  Haewon Nam; Minghao Guo; Hengyong Yu; Keumsil Lee; Ruijiang Li; Bin Han; Lei Xing; Rena Lee; Hao Gao
Journal:  PLoS One       Date:  2019-01-11       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.