Literature DB >> 14709604

Evaluation of coronal CT findings of rare cases of isolated medial orbital wall blow-out fractures.

T Tanaka1, Y Morimoto, S Kito, T Ro, T Masumi, Y Ichiya, T Ohba.   

Abstract

OBJECTIVES: To report rare cases of isolated medial orbital wall blow-out fractures and to evaluate their coronal CT findings.
METHODS: Nine cases of medial orbital wall blow-out fractures, diagnosed by coronal CT in a general medical hospital between 1995 and 1999, were studied. CT was performed using direct coronal acquisition with a slice thickness of 5 mm. Images were obtained at bone window settings. Clinical examination findings from the medical records were used to give information on the cause of injury, ocular symptoms and the days after injury that the CT examination was performed.
RESULTS: Most of the patients (67%) were young male adults. The cause of injury was most frequently the result of fist fighting or athletics (78%). Diplopia and/or limitation of the gaze were the main ocular symptoms (78%). The average time from injury to CT examination was 4 days (range 0-16 days). Seven of the nine patients with medial orbital wall fractures had isolated medial orbital wall blow-out fractures. Herniation of orbital contents toward the ethmoid sinus was observed among all nine fractures. Only three patients (33%) had a swelling and/or medial deviation of the medial rectus muscle, all three having isolated medial orbital wall blow-out fractures.
CONCLUSIONS: Nine cases of medial orbital wall blow-out fractures were examined, seven of which were isolated medial wall blow-out fractures. CT findings of this type of fracture included herniation of the orbital contents toward the ethmoid sinus. However, swelling and/or medial deviation of the medial rectus muscle was also seen.

Entities:  

Mesh:

Year:  2003        PMID: 14709604     DOI: 10.1259/dmfr/12630722

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  2 in total

1.  Comparison of Absorbable Mesh Plate versus Titanium-Dynamic Mesh Plate in Reconstruction of Blow-Out Fracture: An Analysis of Long-Term Outcomes.

Authors:  Woon Il Baek; Han Koo Kim; Woo Seob Kim; Tae Hui Bae
Journal:  Arch Plast Surg       Date:  2014-07-15

2.  The Correlation between the Degree of Enophthalmos and the Extent of Fracture in Medial Orbital Wall Fracture Left Untreated for Over Six Months: A Retrospective Analysis of 81 Cases at a Single Institution.

Authors:  Yun Sik Sung; Chan Min Chung; In Pyo Hong
Journal:  Arch Plast Surg       Date:  2013-07-17
  2 in total