Literature DB >> 14699873

[Implantation of Palmaz stent for limb stenosis of Y-graft: a case report].

Masahiro Sakai1, Shunichi Matsumoto, Itsuma Kamoi, Atsushi Fukuda.   

Abstract

An 81-year-old woman complained of severe right leg claudication in 2000. She had undergone inverted Y-graft placement for infrarenal abdominal aortic aneurysm in 1998. Magnetic resonance angiography (MRA) revealed severe stenosis at the right common iliac graft. Digital subtraction angiography (DSA) demonstrated a rare form of stenosis due to organized thrombus. Stent placement was successfully performed, utilizing a Palmaz stent. The stent has been patent for three years. The patient is asymptomatic and is being followed at our institute.

Entities:  

Mesh:

Year:  2003        PMID: 14699873

Source DB:  PubMed          Journal:  Nihon Igaku Hoshasen Gakkai Zasshi        ISSN: 0048-0428


  1 in total

1.  Successful endovascular repair in two cases of graft limb occlusion after endovascular aneurysm repair for abdominal aortic aneurysms.

Authors:  Katsuyuki Hoshina; Masaaki Kato; Akiyoshi Mikuriya; Nobukazu Ohkubo
Journal:  Surg Today       Date:  2010-04-28       Impact factor: 2.549