Literature DB >> 14698346

On the ultrasonic properties of tendon.

Tanya Garcia1, William J Hornof, Michael F Insana.   

Abstract

The strong dependence of tendon echogenicity on insonation angle is explored by analyzing echo spectra. Combining echo spectra with high-resolution images from several modalities reveals that fluid spaces surrounding fascicles and bundles are likely sources of ultrasonic scatter. Mathematical models of tendon structure are proposed to explain how the anisotropic microstructure of tendon gives rise to angle-dependent echogenicity. Echo spectra from spontaneously damaged equine tendon samples were compared with normal equine tendon and found to exhibit a dramatic decrease in anisotropic properties that appears to be related to the spatial organization and type of collagen generated during repair. Variation in echo spectra with insonation angle is a robust indicator of mechanical damage.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14698346     DOI: 10.1016/s0301-5629(03)01069-x

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Ultrasound in the diagnosis of clinical orthopedics: The orthopedic stethoscope.

Authors:  Alexander Blankstein
Journal:  World J Orthop       Date:  2011-02-18

2.  Analysis of collagen organization in mouse achilles tendon using high-frequency ultrasound imaging.

Authors:  Corinne N Riggin; Joseph J Sarver; Benjamin R Freedman; Stephen J Thomas; Louis J Soslowsky
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

3.  Nonlinear optical microscopy and ultrasound imaging of human cervical structure.

Authors:  Lisa M Reusch; Helen Feltovich; Lindsey C Carlson; Gunnsteinn Hall; Paul J Campagnola; Kevin W Eliceiri; Timothy J Hall
Journal:  J Biomed Opt       Date:  2013-03       Impact factor: 3.170

4.  Ultrasound assessment of transverse carpal ligament thickness: a validity and reliability study.

Authors:  Zhilei Liu Shen; Zong-Ming Li
Journal:  Ultrasound Med Biol       Date:  2012-04-12       Impact factor: 2.998

5.  Influence of tendon tears on ultrasound echo intensity in response to loading.

Authors:  Kayt E Frisch; David Marcu; Geoffrey S Baer; Darryl G Thelen; Ray Vanderby
Journal:  J Biomech       Date:  2014-10-31       Impact factor: 2.712

6.  Increasing Vascular Response to Injury Improves Tendon Early Healing Outcome in Aged Rats.

Authors:  Corinne N Riggin; Stephanie N Weiss; Ashley B Rodriguez; Harina Raja; Mengcun Chen; Susan M Schultz; Chandra M Sehgal; Louis J Soslowsky
Journal:  Ann Biomed Eng       Date:  2022-03-18       Impact factor: 4.219

7.  Is echogenicity a viable metric for evaluating tendon properties in vivo?

Authors:  Stephen M Suydam; Thomas S Buchanan
Journal:  J Biomech       Date:  2014-03-26       Impact factor: 2.712

8.  Quantitative diagnostic method for biceps long head tendinitis by using ultrasound.

Authors:  Shih-Wei Huang; Wei-Te Wang
Journal:  ScientificWorldJournal       Date:  2013-12-07

9.  Modulation of vascular response after injury in the rat Achilles tendon alters healing capacity.

Authors:  Corinne N Riggin; Ashley B Rodriguez; Stephanie N Weiss; Harina A Raja; Mengcun Chen; Susan M Schultz; Chandra M Sehgal; Louis J Soslowsky
Journal:  J Orthop Res       Date:  2020-10-01       Impact factor: 3.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.