Literature DB >> 14698340

In vitro evaluation of ultrasound Doppler strain rate imaging: modification for measurement in a slowly moving tissue phantom.

Knut Matre1, Aymen B Ahmed, Hans Gregersen, Andreas Heimdal, Trygve Hausken, Svein Ødegaard, Odd Helge Gilja.   

Abstract

Doppler strain rate imaging (SRI) was evaluated in vitro using a silicone strip phantom mimicking slowly moving tissue. A test apparatus was developed that enabled controlled strain experiments with variable strain and strain rate to be performed. SRI strain was measured at eight different calculated strains (range 5.7 to 63.4 %) at three different pump speeds with tissue velocity 0.1, 0.5 and 1.0 mm/s. The effect of varying tissue velocity and strain sample size on the measured SRI strain was elaborated. SRI strains agreed well with calculated values for strain when SRI strain was measured as the average over the whole strip cross-section and the strain sample size was 1.9 mm (mean difference = 2.78%, limits of agreement +/- 9.97% for tissue velocity 1.0 mm/s, n = 8). The variance was substantial if single central samples were used, especially for strain sample size of 0.8 mm (mean difference = -7.47%, limits of agreement +/- 20.90 for tissue velocity 0.5 mm/s, n = 24). Increasing the strain sample size to 1.9 mm removed some of the underestimation (giving mean difference of -4.46%, n = 24). We found low intra- and interobserver variation. This study indicates that, for the SRI method to give accurate estimates of strain, strain sample size should be in the region of 2 mm. Averaging over several ultrasound (US) beams increased the accuracy further.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14698340     DOI: 10.1016/j.ultrasmedbio.2003.08.006

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

Review 1.  Gastric accommodation assessed by ultrasonography.

Authors:  Odd Helge Gilja; Johan Lunding; Trygve Hausken; Hans Gregersen
Journal:  World J Gastroenterol       Date:  2006-05-14       Impact factor: 5.742

2.  Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels.

Authors:  Sergio Casciaro; Francesco Conversano; Stefano Musio; Ernesto Casciaro; Christian Demitri; Alessandro Sannino
Journal:  J Mater Sci Mater Med       Date:  2008-12-04       Impact factor: 3.896

3.  Two-dimensional strain imaging of controlled rabbit hearts.

Authors:  Congxian Jia; Ragnar Olafsson; Kang Kim; Theodore J Kolias; Jonathan M Rubin; William F Weitzel; Russell S Witte; Sheng-Wen Huang; Michael S Richards; Cheri X Deng; Matthew O'Donnell
Journal:  Ultrasound Med Biol       Date:  2009-07-17       Impact factor: 2.998

4.  Phase rotation methods in filtering correlation coefficients for ultrasound speckle tracking.

Authors:  Lingyun Huang; Yael Petrank; Sheng-Wen Huang; Congxian Jia; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

5.  Evaluation of ultrasound Tissue Velocity Imaging: a phantom study of velocity estimation in skeletal muscle low-level contractions.

Authors:  Frida Lindberg; Mattias Mårtensson; Christer Grönlund; Lars-Åke Brodin
Journal:  BMC Med Imaging       Date:  2013-06-07       Impact factor: 1.930