| Literature DB >> 14696936 |
M Gandhimathi1, T K Ravi, Susan Kurian Renu.
Abstract
A simple, precise and rapid RP-HPLC method was developed for the determination of repaglinide in pharmaceutical dosage forms. The method was carried out on a Shim-pack, RP-C18 column using a mixture of methanol: 0.1% v/v triethylamine (pH adjusted to 7 with orthophosphoric acid) and detection was done at 235 nm using nimesulide as internal standard. The linearity range was 0.1 to 0.5 microg/ml. The intra-day and inter-day precision were in the range of 0.48 to 1.01 and 0.15 to 1.15, respectively.Entities:
Mesh:
Substances:
Year: 2003 PMID: 14696936 DOI: 10.2116/analsci.19.1675
Source DB: PubMed Journal: Anal Sci ISSN: 0910-6340 Impact factor: 2.081