PURPOSE: The aim of the study was to evaluate the inter- and intrapatient variability of positron emission tomography (PET) measurements of perfusion in advanced solid cancers. EXPERIMENTAL
DESIGN: Thirty-seven patients with predominantly intra-abdominal tumors underwent PET imaging using inhaled C15O2. Repeat data were obtained by scanning five patients twice, 1 week apart, with no intervening therapy. Regional flow and the volume of distribution (V(d)) were measured from dynamic images by use of a one-compartment model. Inter- and intrapatient variability were measured as the coefficient of variability (CV). Data were also obtained for regions of interest in normal liver, spleen, and kidney.
RESULTS: The mean (+/-SD) regional flow in the tumors was 0.46 +/- 0.19 ml(blood)/min/ml(tissue), and the mean V(d) was 0.74 +/- 0.15 ml(blood)/ml(tissue). Variability in tumor flow was greater between (n = 37; CV = 41%) than within (n = 5; CV = 11%) patients. Variability in tumor V(d) was greater between (CV = 21%) than within (CV = 6%) patients. There was a good correlation between the repeat tumor data for both regional flow (rho = 0.82; P = 0.023) and V(d) (rho = 0.89; P = 0.007). Normal tissue variability was also greater between than within patients. In all cases, no statistically significant differences were seen between repeat measurements in the same patient.
CONCLUSIONS: Dynamic C15O2 PET measurements of regional flow are reproducible in patients with predominantly intra-abdominal malignancies and may be useful for the pharmacodynamic evaluation of novel antivascular and antiangiogenic cancer therapeutic agents.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14695134

Source DB:  PubMed          Journal:  Clin Cancer Res        ISSN: 1078-0432            Impact factor:   12.531


  8 in total

Review 1.  Radionuclide imaging of perfusion and hypoxia.

Authors:  George Laking; Pat Price
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

2.  Estimation of intra-operator variability in perfusion parameter measurements using DCE-US.

Authors:  Marianne Gauthier; Ingrid Leguerney; Jessie Thalmensi; Mohamed Chebil; Sarah Parisot; Pierre Peronneau; Alain Roche; Nathalie Lassau
Journal:  World J Radiol       Date:  2011-03-28

3.  Factors affecting the quantitative liver-spleen scan in normal individuals.

Authors:  John C Hoefs; Muhammad Y Sheikh; Heather Guerrero; Norah Milne
Journal:  Dig Dis Sci       Date:  2005-02       Impact factor: 3.199

4.  The use of perfusion CT for the evaluation of therapy combining AZD2171 with gefitinib in cancer patients.

Authors:  Martijn R Meijerink; Hester van Cruijsen; Klaas Hoekman; Matthijs Kater; Cors van Schaik; Jan Hein T M van Waesberghe; Giuseppe Giaccone; Radu A Manoliu
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

Review 5.  Imaging of tumor angiogenesis: functional or targeted?

Authors:  Baris Turkbey; Hisataka Kobayashi; Mikako Ogawa; Marcelino Bernardo; Peter L Choyke
Journal:  AJR Am J Roentgenol       Date:  2009-08       Impact factor: 3.959

Review 6.  Imaging hemodynamics.

Authors:  Dominique Jennings; Natarajan Raghunand; Robert J Gillies
Journal:  Cancer Metastasis Rev       Date:  2008-12       Impact factor: 9.264

7.  Reproducibility of tumor blood flow quantification with 15O-water PET.

Authors:  Martin A Lodge; Heather A Jacene; Roberto Pili; Richard L Wahl
Journal:  J Nucl Med       Date:  2008-10       Impact factor: 10.057

8.  Recommendations for measurement of tumour vascularity with positron emission tomography in early phase clinical trials.

Authors:  Eric O Aboagye; Fiona J Gilbert; Ian N Fleming; Ambros J Beer; Vincent J Cunningham; Paul K Marsden; Dimitris Visvikis; Antony D Gee; Ashley M Groves; Laura M Kenny; Gary J Cook; Paul E Kinahan; Melvyn Myers; Larry Clarke
Journal:  Eur Radiol       Date:  2012-04-04       Impact factor: 5.315