Literature DB >> 14693603

Assessing propofol induction of anesthesia dose using bispectral index analysis.

Ercan Gürses1, Hülya Sungurtekin, Erkan Tomatir, Hakan Dogan.   

Abstract

UNLABELLED: In this study we sought to determine the propofol requirement and hemodynamic effects as guided by bispectral index (BIS) analysis during induction of anesthesia. Sixty patients were enrolled in this study. Propofol, 2 mg/kg, was given to Group I for induction. Propofol was administered for induction until loss of response to verbal commands and until BIS values were around 50 to Groups II and III. After induction, the smallest BIS value was different in Group I. Decreases in total propofol dose were 36% and 43% in Groups II and III respectively as compared with Group I. The dose of propofol assessed by BIS analysis results in an important reduction of propofol requirement without side effects. IMPLICATIONS: Hypotension during induction of anesthesia with propofol is common. This study has shown that propofol requirement assessed by bispectral index analysis during anesthesia induction may decrease the dose and side effects and provide for satisfactory depth of anesthesia.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14693603     DOI: 10.1213/01.ane.0000090314.43496.1d

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  8 in total

Review 1.  Using EEG to monitor anesthesia drug effects during surgery.

Authors:  Leslie C Jameson; Tod B Sloan
Journal:  J Clin Monit Comput       Date:  2006-12       Impact factor: 2.502

2.  Effects on somatosensory and motor evoked potentials of senile patients using different doses of dexmedetomidine during spine surgery.

Authors:  Z Chen; S Lin; W Shao
Journal:  Ir J Med Sci       Date:  2014-09-03       Impact factor: 1.568

3.  Cerebral monitoring in the operating room and the intensive care unit: an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part I: The electroencephalogram.

Authors:  Enno Freye; Joseph V Levy
Journal:  J Clin Monit Comput       Date:  2005-04       Impact factor: 2.502

4.  Comparison of electroencephalogram entropy versus loss of verbal response to determine the requirement of propofol for induction of general anaesthesia.

Authors:  Akasapu Karunakara Rao; Indira Gurajala; Ramachandran Gopinath
Journal:  Indian J Anaesth       Date:  2015-06

5.  Prediction of hemodynamic fluctuations after induction of general anesthesia using propofol in non-cardiac surgery: a retrospective cohort study.

Authors:  Sho Kawasaki; Chikako Kiyohara; Shoji Tokunaga; Sumio Hoka
Journal:  BMC Anesthesiol       Date:  2018-11-10       Impact factor: 2.217

6.  The role of entropy monitoring in reducing propofol requirements during open heart surgeries. A prospective randomized study.

Authors:  Ahmed Said Elgebaly; Mona B El Mourad; Sameh Mohamad Fathy
Journal:  Ann Card Anaesth       Date:  2020 Jul-Sep

7.  Clinical vs. bispectral index-guided propofol induction of anesthesia: A comparative study.

Authors:  Snehdeep Arya; Veena Asthana; Jagdish P Sharma
Journal:  Saudi J Anaesth       Date:  2013-01

8.  Efficacy of Ketofol in Blunting Hypotensive Effects of Propofol during Induction and Its Effect on Intraoperative Anesthetic Requirements and Recovery Profile.

Authors:  Niranjan Kumar; Sunil Rajan; Lakshmi Kumar
Journal:  Anesth Essays Res       Date:  2021-05-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.