Literature DB >> 14693177

Enzyme immunoassay for measurement of murine plasminogen activator inhibitor-1, employing a specific antibody produced by the DNA vaccine method.

Takayuki Yamada1, Akira Takagi, Kyosuke Takeshita, Koji Yamamoto, Masafumi Ito, Tadashi Matsushita, Takashi Murate, Hidehiko Saito, Tetsuhito Kojima.   

Abstract

We developed a sensitive immunoassay to determine the concentration of mouse plasminogen activator inhibitor-1. The assay was a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) based on the production of a specific polyclonal antibody against mouse plasminogen activator inhibitor type-1 (PAI-1) used both as a trapping and detecting antibody. This antibody was raised in a rabbit by direct introduction of the expression vector plasmid DNA encoding mouse PAI-1, instead of conventional immunization with the purified protein. The standard curve was constructed with a recombinant glutathione S-transferase (GST)-mouse PAI-1 fusion protein (GST-mPAI-1) and dose-response of the assay was linear for GST-mPAI-1 between 6.25 and 100 pM. In order to assess the consistency of the assay, we measured PAI-1 antigen in normal mouse pooled plasma several times. We found that the intra-assay and inter-assay coefficients of variation (CV) were 4.8% and 9.2%, respectively, indicating that the ELISA would be sufficiently repeatable and reproducible. In this assay, lipopolysaccharide (LPS)-injected mice showed substantially higher levels (22-fold) of plasma PAI-1 antigen than did control mice (12.5+/-2.4 vs. 0.58+/-0.16 nM), similar to results reported elsewhere. Taken together, the DNA vaccine method is extremely useful for preparing specific antibodies against mouse PAI-1, which can be utilized to establish the ELISA and analyze the profile of PAI-1 distributions in mice under various conditions. This approach might also be useful for immunological investigation of other coagulation factors and related proteins.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14693177     DOI: 10.1016/j.thromres.2003.09.007

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  2 in total

1.  Stress-induced PAI-1 expression is suppressed by pitavastatin in vivo.

Authors:  Koji Yamamoto; Kyosuke Takeshita; Tetsuhito Kojima; Junki Takamatsu
Journal:  Int J Hematol       Date:  2009-04-08       Impact factor: 2.490

2.  Systemic coagulation parameters in mice after treatment with vascular targeting agents.

Authors:  Maike Unruh; Andrea Grunow; Claudia Gottstein
Journal:  Thromb J       Date:  2005-12-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.