Literature DB >> 14692978

Platelet activation during plasma-reduced multicomponent PLT collection: a comparison between COBE Trima and Spectra LRS turbo cell separators.

Paolo Perseghin1, Luca Mascaretti, Tiziana Speranza, Daniela Belotti, Valentina Baldini, Maria Dassi, Mariarosa Riva, Enrico Maria Pogliani, Gianalfredo Sciorelli.   

Abstract

BACKGROUND: The wide diffusion of multicomponent collection in donor apheresis has led to the yielding of different components, such as plasma-reduced platelet-pheresis at high PLT concentration. We investigated whether this collection modality could induce more PLT activation compared to standard plateletpheresis. STUDY DESIGN AND METHODS: Forty-one plateletpheresis collections (20 Trima and 21 Spectra LRS Turbo v.7.0, COBE) were evaluated. Donor, procedure, and product data were recorded. ADP, collagen, and U46619 (a thromboxane-A2 analog)-induced PLT aggregation was investigated in basal (donor) and final (plateletpheresis unit) samples. The expression of PLT activation marker P-selectin (CD62P) was studied using flow cytometry in basal and final samples. In all cases, P-selectin was investigated in final samples after stimulation with ADP to assess for a possible further release of the antigen. Four additional plateletpheresis procedures were performed in donors from Group A, using the traditional, nonplasma-reduced program.
RESULTS: Plateletpheresis obtained by means of the Trima device showed a lower response to in-vitro induced PLT aggregation and a higher percentage of P-selectin-expressing PLT when compared to products obtained using the Spectra device. Moreover, P-selectin release after ADP stimulation was reduced in plateletpheresis units obtained using the Trima device. These differences disappeared when a nonplasma-reduced collection program was used. In-vivo evaluation did not detect any difference between plateletpheresis obtained by means of the two cell separators.
CONCLUSIONS: Plateletpheresis units obtained by means of multicomponent collection show a higher degree of PLT activation compared to traditional plateletpheresis procedures when high-concentration plasma-reduced products are collected. Randomized clinical studies are needed to assess the real impact of these findings in terms of in-vivo efficacy of plasma-reduced plateletpheresis units.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14692978     DOI: 10.1046/j.0041-1132.2004.00613.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  Monitoring of platelet activation in platelet concentrates using transmission electron microscopy.

Authors:  Josef Neumüller; Claudia Meisslitzer-Ruppitsch; Adolf Ellinger; Margit Pavelka; Christof Jungbauer; Renate Renz; Gerda Leitner; Thomas Wagner
Journal:  Transfus Med Hemother       Date:  2013-03-14       Impact factor: 3.747

2.  Platelet responses to agonists in a cohort of highly characterised platelet donors are consistent over time.

Authors:  S F Garner; A Furnell; B C Kahan; C I Jones; A Attwood; P Harrison; A M Kelly; A H Goodall; R Cardigan; W H Ouwehand
Journal:  Vox Sang       Date:  2016-12-21       Impact factor: 2.144

  2 in total