Literature DB >> 14692813

Evaluation of linearity in the clinical laboratory.

Jeffrey S Jhang1, Chung-Che Chang, Daniel J Fink, Martin H Kroll.   

Abstract

CONTEXT: Clinical laboratory assessment of test linearity is often limited to satisfying regulatory requirements rather than integrating this tool into the laboratory quality assurance program. Although an important part of quality control and method validation for clinical laboratories, linearity of clinical tests does not get the attention it deserves.
OBJECTIVE: This article evaluates the concepts and importance of linearity evaluations for clinical tests.
DESIGN: We describe the theory and procedural steps of each linearity evaluation. We then evaluate the statistical methods for each procedure.
RESULTS: Visual assessment, although simple, is subjective. The lack-of-fit error and the 1986 NCCLS EP6-P G test are sensitive to imprecision and assume that the data are first order. Regression analysis, as developed as the polynomial method, is partly based on the experiences of the College of American Pathologists Instrumentation Resource Committee and has proved to be a robust statistical method.
CONCLUSIONS: We provide general guidelines for handling non-linear results from a linearity evaluation. Handling linearity data in an objective manner will aid clinical laboratorians whose goal is to improve the quality of the tests they perform.

Mesh:

Year:  2004        PMID: 14692813     DOI: 10.5858/2004-128-44-EOLITC

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  4 in total

1.  Expanding the Non-Invasive Diagnosis of Acute Rejection in Kidney Transplants Through Detection of Donor-Derived DNA in Urine: Proof-of-Concept Study.

Authors:  Jieun Kim; Dong-Moung Kim; Yu Jin Park; Seung-Tae Lee; Hyon-Suk Kim; Myoung Soo Kim; Beom Seok Kim; Jong Rak Choi
Journal:  Ann Lab Med       Date:  2021-09-01       Impact factor: 3.464

2.  Performance Evaluation of the i-SmartCare 10 Analyzer and Method Comparison of Six Point-of-Care Blood Gas Analyzers.

Authors:  Sang-Mi Kim; Hyung-Doo Park
Journal:  Ann Lab Med       Date:  2022-07-01       Impact factor: 4.941

3.  Bioanalytical method validation: An updated review.

Authors:  Gaurav Tiwari; Ruchi Tiwari
Journal:  Pharm Methods       Date:  2010-10

4.  Differential reporting of fruit and vegetable intake among youth in a randomized controlled trial of a behavioral nutrition intervention.

Authors:  Namrata Sanjeevi; Leah Lipsky; Aiyi Liu; Tonja Nansel
Journal:  Int J Behav Nutr Phys Act       Date:  2019-02-01       Impact factor: 6.457

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.