Literature DB >> 14691666

Clinical study of biocompatibility between open and closed heparin-coated cardiopulmonary bypass circuits.

Hiroyuki Tanaka1, Takanori Oshiyama, Takashi Narisawa, Takanobu Mori, Mikio Masuda, Daijirou Kishi, Takashi Kitou, Shingo Miyazima.   

Abstract

The objective of this study was to investigate the difference between the closed circuit system and the open circuit system in clinical heparin-coated cardiopulmonary bypass (CPB) circuits with a centrifugal pump. We evaluated the coagulation, fibrinolysis, and inflammatory response in valvular heart surgery. Nineteen patients were assigned at random to a group for the closed circuit system or the open circuit system. This is the first report on the effect of a closed circuit in valvular surgery. We measured the platelet count, white blood cell count, plasma fibrinogen concentration, thrombin-antithrombin III complex, plasmin-Alpha2 plasmin inhibitor complex, D-dimer, interleukin-6, polymorphic neutrophil-elastase, and the plasma free hemoglobin. Blood samples were collected before the start of perfusion, 15 and 60 min after the start of perfusion, 60 min after the administration of protamine, and 1 day after the operation. During the perfusion, coagulation, fibrinolysis, and inflammatory responses were activated; however, no significant differences between the two groups were noted. In this clinical investigation with suction and the cell saving system, the closed circuit was not found to be superior to the open circuit with regard to biocompatibility.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14691666     DOI: 10.1007/s10047-003-0237-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  3 in total

1.  Microbubble generation and transmission of medtronic's affinity hardshell venous reservoir and collapsible venous reservoir bag: an in-vitro comparison.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2011-09

Review 2.  Attenuating the Systemic Inflammatory Response to Adult Cardiopulmonary Bypass: A Critical Review of the Evidence Base.

Authors:  R Clive Landis; Jeremiah R Brown; David Fitzgerald; Donald S Likosky; Linda Shore-Lesserson; Robert A Baker; John W Hammon
Journal:  J Extra Corpor Technol       Date:  2014-09

3.  Use of a soft reservoir bag in a fully heparin-coated closed-loop cardiopulmonary bypass system for distal aortic perfusion during aortic surgery.

Authors:  Norihiko Shiiya; Kenji Matsuzaki; Takashi Kunihara; Keishu Yasuda
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.