Literature DB >> 14689533

Sonographic assessment of the cervix before, during and after a uterine contraction is effective in predicting the course of labor.

M Saito1, S Kozuma, A Kikuchi, M Sakai, T Fujii, N Unno, T Okai, Y Taketani.   

Abstract

OBJECTIVE: To investigate whether the degree of change in cervical length during a uterine contraction is predictive of subsequent progression of labor.
METHODS: The subjects were 73 uncomplicated parturient women at term. We observed the cervix before, during and after a uterine contraction by transvaginal ultrasound in the first stage of labor and determined the degree of cervical shortening during the contraction relative to the cervical length before contraction. We related the degree of cervical shortening to labor patterns at the time of the ultrasound examination, which were retrospectively determined by reviewing the partogram.
RESULTS: The cervix was shortened in length by about 50% on average during a uterine contraction in the normal course of labor. The degree of cervical shortening was significantly greater in the normal latent and active phases than it was in the prolonged latent phase, protracted active phase and false labor, whereas there were no differences between the former two phases nor between the latter three phases. Nulliparous and parous women exhibited almost the same degree of shortening in the normal latent and active phases.
CONCLUSIONS: Real-time ultrasound observation of the cervix during uterine contraction could help differentiate inefficient uterine contractions from normal ones and thus predict the subsequent course of labor. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 14689533     DOI: 10.1002/uog.927

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  2 in total

1.  Growth-profile configuration for specific deformations of tubular organs: A study of growth-induced thinning and dilation of the human cervix.

Authors:  Kun Gou; Seungik Baek; Marvin M F Lutnesky; Hai-Chao Han
Journal:  PLoS One       Date:  2021-08-11       Impact factor: 3.240

2.  Automatic evaluation of progression angle and fetal head station through intrapartum echographic monitoring.

Authors:  Sergio Casciaro; Francesco Conversano; Ernesto Casciaro; Giulia Soloperto; Emanuele Perrone; Gian Carlo Di Renzo; Antonio Perrone
Journal:  Comput Math Methods Med       Date:  2013-09-09       Impact factor: 2.238

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.