Literature DB >> 14689529

Uterine artery blood flow velocity waveforms during uterine contractions.

H Li1, S Gudmundsson, P Olofsson.   

Abstract

OBJECTIVE: No quantitative or qualitative Doppler velocimetry classification of vascular flow resistance covering all stages of forward and reversed flows exists. The objective of this study was to characterize uterine artery (UtA) flow velocity waveforms (FVWs) obtained during an oxytocin challenge test (OCT) and compare them to FVWs in spontaneous normal labor.
METHODS: Uterine artery Doppler velocimetry was performed during and between uterine contractions in 61 high-risk pregnancies subjected to an OCT and in 20 normal pregnancies undergoing spontaneous labor. FVWs were classified relative to the presence of forward/absent/reversed flow during systole and diastole, and the time-averaged flow velocity over the heart cycle.
RESULTS: Eleven different FVW classes were identified. No relationship between FVWs recorded during uterine inertia and contractions was found (P >/= 0.2). In both groups, only forward FVWs were recorded between contractions, whereas during contractions flow reversal was more common in the OCT group (P </= 0.002). In cases of predominantly reversed flow, a reciprocal relationship to FVW classes recorded in the contralateral artery was found.
CONCLUSIONS: UtA FVW patterns recorded during uterine contractions were not predicted by flow patterns recorded during uterine inertia. Reversal of flow direction was more common during oxytocin-induced uterine contractions than during spontaneous contractions. In cases of predominantly reversed flow, domains of the uterus may be supplied by blood from the contralateral UtA. These observations give new insights into the circulatory dynamics of the uterus during labor, and also point to a possible vasoconstrictory effect in the UtAs of oxytocin at high concentrations. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14689529     DOI: 10.1002/uog.921

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

Review 1.  The peripheral chemoreflex: indefatigable guardian of fetal physiological adaptation to labour.

Authors:  Christopher A Lear; Guido Wassink; Jenny A Westgate; Jan G Nijhuis; Austin Ugwumadu; Robert Galinsky; Laura Bennet; Alistair J Gunn
Journal:  J Physiol       Date:  2018-04-26       Impact factor: 5.182

2.  Comparative evaluation of epidural bupivacaine - dexmedetomidine and bupivacaine -fentanyl on Doppler velocimetry of uterine and umbilical arteries during labor.

Authors:  Mohamed Fouad Selim; Ali Mohamed Ali Elnabtity; Ali Mohamed Ali Hasan
Journal:  J Prenat Med       Date:  2012-07

3.  Uterine artery impedance during the first eight postpartum weeks.

Authors:  L Guedes-Martins; A R Gaio; J Saraiva; A Cunha; F Macedo; H Almeida
Journal:  Sci Rep       Date:  2015-03-05       Impact factor: 4.379

4.  Systematic review to investigate the safety of induction and augmentation of labour among pregnant women with iron-deficiency anaemia.

Authors:  Kathryn Bunch; Nia Roberts; Marian Knight; Manisha Nair
Journal:  BMJ Open       Date:  2018-12-19       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.