Literature DB >> 1468874

Measurement of myocardial perfusion and cardiac output using intravenous injection methods by ultrafast (cine) computed tomography.

J A Rumberger1, M R Bell.   

Abstract

Ultrafast (or cine) computed tomography (CT) uses a novel scanning electron beam technology to obtain multi-level images of the beating heart in rapid succession. Recent investigations have demonstrated that it can be used to define the transit of iodinated contrast media through the cardiac chambers and myocardium. Using classical indicator dilution principles and rapid intravenous injection of iodinated contrast media, ultrafast CT can quantify cardiac output and, to a limited extent, myocardial perfusion. A caveat to the application requires that careful calibration be made on a subject-by-subject basis prior to quantification of cardiac output. Although global myocardial perfusion and flow reserve can be evaluated by ultrafast CT, spatially variable imaging artifacts may limit the application in all regions of the left ventricular myocardium. Advances in study design, image reconstruction and post-image processing continue. Ultrafast CT technology offers a means to define cardiac anatomy, function and flow in man rapidly, conveniently and accurately in a noninvasive fashion employing intravenous contrast media injection.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1468874     DOI: 10.1097/00004424-199212002-00008

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  10 in total

Review 1.  Quantitative and qualitative analysis and interpretation of CT perfusion imaging.

Authors:  Carolina Valdiviezo; Marietta Ambrose; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

2.  [Quantitative determination of left ventricular myocardial perfusion with electron beam computerized tomography].

Authors:  R Rienmüller; C Baumgartner; R Kern; S Harb; R Aigner; G Fueger; W Weihs
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

3.  Myocardial perfusion imaging with first-pass computed tomographic imaging: Measurement of coronary flow reserve in an animal model of regional hyperemia.

Authors:  Timothy F Christian; Mei Lee Frankish; Jennifer H Sisemoore; Madeline R Christian; George Gentchos; Stephen P Bell; Michael Jerosch-Herold
Journal:  J Nucl Cardiol       Date:  2010-05-15       Impact factor: 5.952

4.  A simple method to estimate cardiac function during routine multi-row detector CT exams.

Authors:  Piet K Vanhoenacker; Lieven R Van Hoe
Journal:  Eur Radiol       Date:  2007-02-03       Impact factor: 5.315

Review 5.  CT-based myocardial perfusion imaging-practical considerations: acquisition, image analysis, interpretation, and challenges.

Authors:  Vishal C Mehra; Marietta Ambrose; Carolina Valdiviezo-Schlomp; Karl H Schuleri; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  J Cardiovasc Transl Res       Date:  2011-06-14       Impact factor: 4.132

Review 6.  Assessment of myocardial perfusion using contrast-enhanced MR imaging: current status and future developments.

Authors:  A Mühler
Journal:  MAGMA       Date:  1995-03       Impact factor: 2.310

Review 7.  CT perfusion: ready for prime time.

Authors:  Marietta S Ambrose; Carolina Valdiviezo; Vishal Mehra; Albert C Lardo; Joao A C Lima; Richard T George
Journal:  Curr Cardiol Rep       Date:  2011-02       Impact factor: 2.931

Review 8.  Evaluation of Myocardial Perfusion by Computed Tomography - Principles, Technical Background and Recommendations.

Authors:  Tiago Augusto Magalhães; Roberto Caldeira Cury; Rodrigo Julio Cerci; José Rodrigues Parga Filho; Ilan Gottlieb; Marcelo Souto Nacif; Ibraim Masciarelli Pinto; Carlos Eduardo Rochitte; Fabio Vilas-Boas; Paulo R Schvartzman
Journal:  Arq Bras Cardiol       Date:  2019-11-04       Impact factor: 2.000

9.  Role of Perfusion CT Differentiating Hemangiomas from Malignant Hepatic Lesions.

Authors:  Jagjeet Singh; Sanjiv Sharma; Neeti Aggarwal; R G Sood; Shikha Sood; Ravinder Sidhu
Journal:  J Clin Imaging Sci       Date:  2014-02-27

10.  Optimal dilution of contrast medium for quantitating parenchymal blood volume using a flat-panel detector.

Authors:  Takumi Kuriyama; Nobuyuki Sakai; Mikiya Beppu; Chiaki Sakai; Hirotoshi Imamura; Iwao Kojima; Katsuhiro Masago; Nobuyuki Katakami
Journal:  J Int Med Res       Date:  2017-07-31       Impact factor: 1.671

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.