Improved detection of microbubble signals using power M-mode Doppler.

Maher Saqqur1, Naeem Dean, Marcia Schebel, Michael D Hill, Abdul Salam, Ashfaq Shuaib, Andrew M Demchuk.   

Abstract

UNLABELLED: Background- Power motion-mode transcranial Doppler (TCD) (PMD) is a new, multigated technique that may simplify and enhance detection of embolus. We developed criteria for emboli detection using PMD. Then, we performed a blinded comparison of transcranial PMD with single-gate spectral TCD in TCD bubble study patients.
METHODS: Patients with right-to-left shunt as detected with standard TCD were selected for this study. The international emboli criteria for spectral TCD were used. We defined novel PMD criteria for detecting emboli signature on PMD as follows: (1) signature at least 3 dB higher than the highest spontaneous PMD display of background blood flow; (2) embolic signature reflects motion in one direction at a minimum spatial extent of 7.5 mm and temporal extent of 30 ms; (3) embolus must traverse a prespecified depth. Each study was blindly assessed for microbubble signals (MBS) count on either modality.
RESULTS: Thirty-six patients were included in the study. Mean age was 44.4 (SD 14.4), 50% were male, and median time from stroke onset to TCD bubble test was 12 days. Median MBS count in middle cerebral arteries (MCA) was 4 on both modalities. Spectral TCD MBS counts were highly correlated (rho=0.97) with PMD MBS counts in MCA and similarly in anterior cerebral arteries (ACA) (rho=0.79). When PMD microbubble counts in the ACA and MCA were summed, a clear 2-fold difference emerged between 2 modalities (P<0.001).
CONCLUSIONS: When compared with spectral TCD, PMD detects more MBS with higher counts by identifying ACA as well as MCA emboli. Pitfalls of overcounting emboli with PMD can be avoided by following such criteria.

Entities:  

Mesh:

Year:  2003        PMID: 14684775     DOI: 10.1161/01.STR.0000106771.62928.66

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  4 in total

Review 1.  Advances in transcranial Doppler ultrasonography.

Authors:  Georgios Tsivgoulis; Andrei V Alexandrov; Michael A Sloan
Journal:  Curr Neurol Neurosci Rep       Date:  2009-01       Impact factor: 5.081

2.  Patent foramen ovale in severe obstructive sleep apnea: clinical features and effects of closure.

Authors:  Zarrin F Shaikh; Jay Jaye; Neil Ward; Atul Malhotra; Manuel de Villa; Michael I Polkey; Michael J Mullen; Mary J Morrell
Journal:  Chest       Date:  2013-01       Impact factor: 9.410

3.  Patent foramen ovale is not associated with hypoxemia in severe chronic obstructive pulmonary disease and does not impair exercise performance.

Authors:  Zarrin F Shaikh; Julia L Kelly; Dinesh Shrikrishna; Manuel de Villa; Michael J Mullen; Nicholas S Hopkinson; Mary J Morrell; Michael I Polkey
Journal:  Am J Respir Crit Care Med       Date:  2014-03-01       Impact factor: 21.405

4.  Reliability of Hand-Held Transcranial Doppler with M-mode Ultrasound in Middle Cerebral Artery Measurement.

Authors:  Paula Muñoz Venturelli; Alejandro M Brunser; Javier Gaete; Sergio Illanes; Javiera López; Verónica V Olavarría; Andrés Reccius; Pablo Brinck; Francisca González; Gabriel Cavada; Pablo M Lavados
Journal:  J Med Ultrasound       Date:  2017-01-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.