Literature DB >> 14684621

Detection of human polyomaviruses in urine from bone marrow transplant patients: comparison of electron microscopy with PCR.

Stefan S Biel1, Andreas Nitsche, Andreas Kurth, Wolfgang Siegert, Muhsin Ozel, Hans R Gelderblom.   

Abstract

BACKGROUND: We studied electron microscopy (EM) as an appropriate test system for the detection of polyomavirus in urine samples from bone marrow transplant patients.
METHODS: We evaluated direct EM, ultracentrifugation (UC) before EM, and solid-phase immuno-EM (SPIEM). The diagnostic accuracy of EM was studied by comparison with a real-time PCR assay on 531 clinical samples.
RESULTS: The detection rate of EM was increased by UC and SPIEM. On 531 clinical urine samples, the diagnostic sensitivity of EM was 47% (70 of 149) with a specificity of 100%. We observed a linear relationship between viral genome concentration and the proportion of urine samples positive by EM, with a 50% probability for a positive EM result for urine samples with a polyomavirus concentration of 10(6) genome-equivalents (GE)/mL; the probability of a positive EM result was 0% for urine samples with <10(3) GE/mL and 100% for urine samples containing 10(9) GE/mL.
CONCLUSIONS: UC/EM is rapid and highly specific for polyomavirus in urine. Unlike real-time PCR, EM has low sensitivity and cannot quantify the viral load.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14684621     DOI: 10.1373/clinchem.2003.024539

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  9 in total

Review 1.  Modern uses of electron microscopy for detection of viruses.

Authors:  Cynthia S Goldsmith; Sara E Miller
Journal:  Clin Microbiol Rev       Date:  2009-10       Impact factor: 26.132

2.  Exosome-loaded dendritic cells elicit tumor-specific CD8+ cytotoxic T cells in patients with glioma.

Authors:  Ning Bu; Haiqin Wu; Bingzhong Sun; Guilian Zhang; Shuqin Zhan; Ru Zhang; Le Zhou
Journal:  J Neurooncol       Date:  2011-02-19       Impact factor: 4.130

3.  Presence of urinary Haufen accurately predicts polyomavirus nephropathy.

Authors:  Harsharan K Singh; Kenneth A Andreoni; Victoria Madden; Karin True; Randal Detwiler; Karen Weck; Volker Nickeleit
Journal:  J Am Soc Nephrol       Date:  2009-01-21       Impact factor: 10.121

4.  Detection of infectious poxvirus particles.

Authors:  Andreas Nitsche; Daniel Stern; Heinz Ellerbrok; Georg Pauli
Journal:  Emerg Infect Dis       Date:  2006-07       Impact factor: 6.883

5.  Detection limit of negative staining electron microscopy for the diagnosis of bioterrorism-related micro-organisms.

Authors:  M Laue; N Bannert
Journal:  J Appl Microbiol       Date:  2010-08-19       Impact factor: 3.772

Review 6.  The role of electron microscopy in the rapid diagnosis of viral infections--review.

Authors:  J Schramlová; S Arientová; D Hulínská
Journal:  Folia Microbiol (Praha)       Date:  2010-03-25       Impact factor: 2.099

7.  Confirmation of electron microscopy results by direct testing of viruses adhered to grids using nucleic acid amplification techniques.

Authors:  Christina K Johnsen; Blenda Böttiger; Jens Blom
Journal:  J Virol Methods       Date:  2006-01-18       Impact factor: 2.014

8.  Ultrasonography in the diagnosis of hemorrhagic cystitis - a complication of bone marrow transplantation in pediatric oncology patients.

Authors:  Urszula Zaleska-Dorobisz; Anna Biel; Dąbrówka Sokołowska-Dąbek; Cyprian Olchowy; Mateusz Łasecki
Journal:  J Ultrason       Date:  2014-09-30

9.  The scanning electron microscope in microbiology and diagnosis of infectious disease.

Authors:  Christine G Golding; Lindsey L Lamboo; Daniel R Beniac; Timothy F Booth
Journal:  Sci Rep       Date:  2016-05-23       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.