Literature DB >> 14681091

Polyurethane grafts: a viable alternative for dialysis arteriovenous access?

Chan Wearn Peng1, Seck Guan Tan.   

Abstract

Polyurethane grafts, promoted for their self-sealing properties and low complication rates, were recently introduced for hemodialysis access. We review our experience with this graft material to determine its complication and patency rates. Between January 1995 and December 1999, 118 patients, 75 female and 43 male, with a mean age of 51 years, had a total of 163 polyurethane arteriovenous grafts inserted. The grafts were mostly 6 mm in diameter (69.3%), placed in a loop configuration (91.4%) in the forearm (49.7%). The median follow-up period was 12 months. The grafts were first cannulated for hemodialysis at a median time of 19 days after implantation, with 12% used within 3 days. Thrombosis and infection were the most common complications at rates of 32.7% and 30.0%, respectively. Infection was the most common cause of graft loss (61.5%). These complications were amenable to salvage intervention. The 1-year primary and secondary patency rates were 73% and 86%, respectively; the 3-year secondary patency rate, 72%. The 1-year serviceability rate was 64%. With satisfactory patency rates and the advantage of its self-sealing properties permitting early cannulation, polyurethane grafts provide a viable alternative for hemodialysis access. Early recognition and appropriate management of complications can prolong graft survival.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14681091     DOI: 10.1177/021849230301100409

Source DB:  PubMed          Journal:  Asian Cardiovasc Thorac Ann        ISSN: 0218-4923


  4 in total

1.  Patency rate and complications of polytetrafluoroethylene grafts compared with polyurethane grafts for hemodialysis access.

Authors:  Hassan Ravari; Gholam Hossein Kazemzade; Mohammad Hadi Saied Modaghegh; Patricia Khashayar
Journal:  Ups J Med Sci       Date:  2010-03-11       Impact factor: 2.384

2.  Sustained release of vancomycin from novel biodegradable nanofiber-loaded vascular prosthetic grafts: in vitro and in vivo study.

Authors:  Kuo-Sheng Liu; Cheng-Hung Lee; Yi-Chuan Wang; Shih-Jung Liu
Journal:  Int J Nanomedicine       Date:  2015-01-29

3.  An immediate access dialysis graft designed to prevent needle-related complications: Results from the initial pre-clinical studies.

Authors:  Shawn M Gage; Michael Lawson; Craig Nichols; Dalton Sycks; Roberto J Manson; Joseph A Knight
Journal:  J Vasc Access       Date:  2019-09-16       Impact factor: 2.283

4.  Biological Evaluation of Flexible Polyurethane/Poly l-Lactic Acid Composite Scaffold as a Potential Filler for Bone Regeneration.

Authors:  Yuk Fai Lui; Wing Yuk Ip
Journal:  Materials (Basel)       Date:  2017-09-13       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.