Literature DB >> 14680576

[The effect of tooth preparation design on the CAD/CAM all-ceramic coping crown's fitness].

Yun-feng Zhao1, Hua-rong Wang, Yong Li.   

Abstract

OBJECTIVE: To study the effect of tooth preparation design on fitness of CAD/CAM all-ceramic coping crown.
METHODS: The tooth preparation comprised 2 types of occlusal convergence (10 degrees, 20 degrees), 2 margin forms (shoulder, chamfer). The MC coping were milled by Cerec 2 CAD/CAM system, cemented, embedded, sectioned, and measured at 10 sites to obtain the data of margin, shoulder, axial surface, occlusal surface fitness.
RESULTS: The coping's fitness was influenced by convergence angle and margin form. The coping's fitness was very nice (101.7 approximately 127.9) microm when the coping with 20 degrees occlusal convergence angle. Those coping with 20 degrees occlusal convergence and chamfer margin in tooth preparation provided the best fitness, its cement film thickness in margin was (40.1 +/- 11.8) microm.
CONCLUSIONS: The 20 degrees occlusal convergence and chamfer margin can be used for CAD/CAM all-ceramic crown in clinical application.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14680576

Source DB:  PubMed          Journal:  Zhonghua Kou Qiang Yi Xue Za Zhi        ISSN: 1002-0098


  1 in total

1.  Evaluation of fit of zirconia posterior bridge structures constructed with different scanning methods and preparation angles.

Authors:  Raquel C Oyagüe; M Isabel Sánchez-Jorge; Andrés Sánchez Turrión
Journal:  Odontology       Date:  2010-07-23       Impact factor: 2.634

  1 in total