Subareolar sentinel node biopsy for multiple breast cancers.

Rakhshanda Layeeque1, Ronda Henry-Tillman, Soheila Korourian, Rena Kass, V Suzanne Klimberg.   

Abstract

BACKGROUND: Sentinel lymph node biopsy (SLNB) is deemed suitable only for unifocal breast cancers since multiple foci of cancers may drain to different nodes. We hypothesized that subareolar injection (SI) could identify the sentinel lymph nodes (SLN) accurately in patients with multiple cancers (MC) in the breast.
METHODS: We prospectively employed SI of lymphazurin or technetium sulfur colloid, or both, for the identification of SLN in patients with MC in the breast. All patients underwent axillary dissection to compute the accuracy of SLNB.
RESULTS: Forty patients presented with MC in the same breast between January 1996 and July 2002. Fifty-two percent (21 of 40) of patients had involvement of more than 1 quadrant; 18% (7 of 40) had more than 1 histologic type of cancers. SLNs were successfully identified in 100% of patients. Axillary disease was present in 63% (25 of 40) of patients. Sensitivity of SLNB was 100% and false negative rate was 0%. The SLN was the only node involved in 45% (18 of 40) of patients.
CONCLUSIONS: SLNB using the SI technique may be an alternative to complete axillary dissection in patients with multiple breast cancers.

Entities:  

Mesh:

Year:  2003        PMID: 14672787     DOI: 10.1016/j.amjsurg.2003.08.014

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  4 in total

1.  Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT).

Authors:  O R Brouwer; L Vermeeren; I M C van der Ploeg; R A Valdés Olmos; C E Loo; L M Pereira-Bouda; F Smit; P Neijenhuis; B C Vrouenraets; F Sivro-Prndelj; S M Jap-a-Joe; P J Borgstein; E J Th Rutgers; H S A Oldenburg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-04-24       Impact factor: 9.236

2.  False negative rate of sentinel lymph node biopsy in multicentric and multifocal breast cancers may be higher in cases with large additive tumor burden.

Authors:  Regina M Fearmonti; Larissa I Batista; Funda Meric-Bernstam; Isabelle Bedrosian; Henry M Kuerer; Kelly K Hunt; S Eva Singletary; Gildy V Babiera
Journal:  Breast J       Date:  2009-09-07       Impact factor: 2.431

3.  Complications of methylene blue dye in breast surgery: case reports and review of the literature.

Authors:  Fj Reyes; Mb Noelck; C Valentino; L Grasso-Lebeau; Je Lang
Journal:  J Cancer       Date:  2010-12-08       Impact factor: 4.207

Review 4.  Contraindications of sentinel lymph node biopsy: are there any really?

Authors:  George M Filippakis; George Zografos
Journal:  World J Surg Oncol       Date:  2007-01-29       Impact factor: 2.754

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.