Literature DB >> 14672679

Reverse dorsal digital and intercommissural flaps used for digital reconstruction.

E Keramidas1, S Rodopoulou, N Metaxotos, P Panagiotou, T Iconomou, J Ioannovich.   

Abstract

Reverse dorsal digital and intercommissural flaps offer a simple and versatile option for skin cover of distal finger defects, especially when other local flaps are not available. Twenty-one reverse dorsal digital flaps were used, on an outpatient basis, to cover dorsal soft tissue defects over or beyond the PIP joint. All the flaps were transposed as reverse island flaps. The average size of the defects was 2.5 cm(2) and they were all used to cover exposed tendon, bone, joint or a combination. Twenty flaps survived completely and did not present any feature of circulatory difficulty. Marginal necrosis of one flap was noticed, while two patients complained of swollen finger 6 months later. No morbidity was reported and the patients maintained good range of motion. Various other types of flaps that have been used to reconstruct distal digital skin defects are reviewed and compared with the reverse dorsal digital and metacarpal flaps.

Entities:  

Mesh:

Year:  2004        PMID: 14672679     DOI: 10.1016/j.bjps.2003.10.010

Source DB:  PubMed          Journal:  Br J Plast Surg        ISSN: 0007-1226


  4 in total

1.  Arterial anatomical basis of the dorsal digito-metacarpal flap for long fingers.

Authors:  Julien Beldame; Eric Havet; Isabelle Auquit-Auckbur; Benjamin Lefebvre; Jean-Philippe Mure; Fabrice Duparc
Journal:  Surg Radiol Anat       Date:  2008-04-11       Impact factor: 1.246

2.  First dorsal metacarpal artery flap with dorsal digital nerve with or without dorsal branch of the proper digital nerve produces comparable short-term sensory outcomes.

Authors:  Shi-Ming Feng; Jia-Ju Zhao; Filippo Migliorini; Nicola Maffulli; Wei Xu
Journal:  J Orthop Surg Res       Date:  2021-11-18       Impact factor: 2.359

3.  Innervated Reconstruction of Fingertip Degloving Injury Using a Dorsal Digital Perforator Flap Combined With a Cross-Finger Flap.

Authors:  Tongfu Wang; Li Wang; Hui Wang; Wenlong Zhang; Zhiliang Yu; Jingyu Zhang
Journal:  Ann Plast Surg       Date:  2022-03-07       Impact factor: 1.763

4.  Double cross finger flaps from the middle to the index or ring finger: A case series of 4 patients with an emphasis on donor finger morbidity.

Authors:  Omar M Al-Qattan; Abdulaziz A Almobarak; Mohammad M Al-Qattan
Journal:  Int J Surg Case Rep       Date:  2018-03-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.