Literature DB >> 14672568

Time-lapsed microstructural imaging of bone failure behavior.

Ara Nazarian1, Ralph Müller.   

Abstract

Many bones within the axial and appendicular skeleton are subjected to repetitive loading during the course of ordinary daily activities. If this loading is of sufficient magnitude or duration, failure of the bone tissue may result. Until recently the structural analysis of these fractures has been limited to two-dimensional sections. Due to the inherent destructiveness of this method, dynamic assessment of fracture progression has not been possible. An image-guided technique to analyze structural failure has been developed utilizing step-wise micro-compression in combination with time-lapsed micro-computed tomographic imaging. This technique allows, for the first time, direct three-dimensional visualization and quantification of fracture initiation and progression on the microscopic level and relates the global failure properties of trabecular bone to those of the individual trabeculae. The goals of this project were first to design and fabricate a novel micro-mechanical testing system, composed of a micro-compression device and a material testing and data acquisition system; and second, to validate the testing system to perform step-wise testing of trabecular bone specimens based on image-guided failure analysis. Due to the rate dependant properties of bone, stress relaxation was a concerning factor with respect to the step-wise testing method. In order to address these concerns, the results of the step-wise testing method were compared to those obtained from a conventional continuous test (considered to be the gold standard for the step-wise compressive mechanical testing) over the same total strain range and testing conditions. This was performed using porous aluminum alloy samples with highly reproducible and homogenous structural properties as well as trabecular bone samples from a single whale vertebra. Five cylinders from aluminum foam and trabecular whale bone each were compressed and imaged in a step-wise fashion from 0% to 20% strain at intervals of 2%, 4%, 8%, 12%, 16% and 20%. Mechanical properties obtained from the continuous and step-wise methods were not significantly different for both aluminum foam and whale bone specimens (p>0.05). Both testing methods yielded very similar stress-strain graphs with almost identical elastic and plastic regions with overlaying standard error bars for both whale bone and aluminum foam specimens. This was further concurred by performing regression analyses between the stress data from both testing methods (r(2)=0.98 for whale bone and aluminum foam specimens). Animations of fracture initiation and progression revealed that failure always occurred in local bands with the remaining regions of the structure largely unaffected independent of structure type. In conclusion, we found step-wise micro-compression to be a valid approach for image-guided failure assessment (IGFA) with high precision and accuracy as compared to classical continuous testing. We expect findings from upcoming studies of IGFA of human vertebral bone to improve our understanding of the relative importance of densitometric, morphological, and loading factors in the etiology of spontaneous fractures of the spine. Eventually, this improved understanding may lead to more successful approaches to the prevention of age-related fatigue fractures.

Entities:  

Mesh:

Year:  2004        PMID: 14672568     DOI: 10.1016/s0021-9290(03)00254-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  27 in total

Review 1.  Trabecular bone failure at the microstructural level.

Authors:  Ralph Müller; G Harry van Lenthe
Journal:  Curr Osteoporos Rep       Date:  2006-06       Impact factor: 5.096

2.  Age-related changes in trabecular bone microstructures: global and local morphometry.

Authors:  M Stauber; R Müller
Journal:  Osteoporos Int       Date:  2005-12-31       Impact factor: 4.507

3.  Mechanical properties of open-cell foam synthetic thoracic vertebrae.

Authors:  Amy E Johnson; Tony S Keller
Journal:  J Mater Sci Mater Med       Date:  2007-09-20       Impact factor: 3.896

4.  Mechanical loading causes detectable changes in morphometric measures of trabecular structure in human cancellous bone.

Authors:  Yener N Yeni; Brenda Wu; Lily Huang; Daniel Oravec
Journal:  J Biomech Eng       Date:  2013-05       Impact factor: 2.097

Review 5.  Hierarchical microimaging of bone structure and function.

Authors:  Ralph Müller
Journal:  Nat Rev Rheumatol       Date:  2009-07       Impact factor: 20.543

6.  Analysis of sintered polymer scaffolds using concomitant synchrotron computed tomography and in situ mechanical testing.

Authors:  A Dhillon; P Schneider; G Kuhn; Y Reinwald; L J White; A Levchuk; F R A J Rose; R Müller; K M Shakesheff; C V Rahman
Journal:  J Mater Sci Mater Med       Date:  2011-09-10       Impact factor: 3.896

7.  Vertebral fragility and structural redundancy.

Authors:  Aaron J Fields; Shashank Nawathe; Senthil K Eswaran; Michael G Jekir; Mark F Adams; Panayiotis Papadopoulos; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2012-10       Impact factor: 6.741

8.  Theoretical bounds for the influence of tissue-level ductility on the apparent-level strength of human trabecular bone.

Authors:  Shashank Nawathe; Frédéric Juillard; Tony M Keaveny
Journal:  J Biomech       Date:  2013-03-14       Impact factor: 2.712

9.  Model-Independent 3D Descriptors of Vertebral Cancellous Bone Architecture.

Authors:  Ian H Parkinson; Danielle Forbes; Peter Sutton-Smith; Nicola L Fazzalari
Journal:  J Osteoporos       Date:  2009-12-31

10.  Quantitative, 3D Visualization of the Initiation and Progression of Vertebral Fractures Under Compression and Anterior Flexion.

Authors:  Timothy M Jackman; Amira I Hussein; Cameron Curtiss; Paul M Fein; Anderson Camp; Lidia De Barros; Elise F Morgan
Journal:  J Bone Miner Res       Date:  2015-12-24       Impact factor: 6.741

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.