Literature DB >> 14671699

Treatment of a late-appearing proximal type-1 endoleak after Ancure graft with an AneuRx cuff--a case report.

Dimitri Stefanidis1, Andy C Chiou, Vikram Kashyap, Boulos Toursarkissian.   

Abstract

The authors describe the case of a patient who developed a type-1 proximal endoleak 10 months after Ancure stent graft placement, despite the lack of stent migration or measurable neck dilatation. The patient had been under observation for a persistent type-2 endoleak and was noted to have an increase in his aneurysm size. The use of an uncovered stent was unsuccessful, and he required a covered proximal extension cuff. This led to a resolution of the endoleak. Implications in terms of surveillance and possible etiologies are discussed.

Entities:  

Mesh:

Year:  2003        PMID: 14671699     DOI: 10.1177/153857440303700608

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089


  2 in total

1.  Long-term results of aortic banding for complex infrarenal neck anatomy and type I endoleak after endovascular abdominal aortic aneurysm repair.

Authors:  Zvonimir Krajcer; Kathryn G Dougherty; Igor D Gregoric
Journal:  Tex Heart Inst J       Date:  2012

2.  Successful Aortic Banding for Type IA Endoleak Due to Neck Dilatation after Endovascular Abdominal Aortic Aneurysm Repair: Case Report.

Authors:  Yasushi Tashima; Koichi Tamai; Takehiro Shirasugi; Kenichiro Sato; Takahiro Yamamoto; Yusuke Imamura; Atsushi Yamaguchi; Hideo Adachi; Toshiyuki Kobinata
Journal:  Ann Vasc Dis       Date:  2017-09-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.