Literature DB >> 14671244

Detection of reversed basilar flow with power-motion Doppler after acute occlusion predicts favorable outcome.

Marc Ribo1, Zsolt Garami, Ken Uchino, Joon Song, Carlos A Molina, Andrei V Alexandrov.   

Abstract

BACKGROUND AND
PURPOSE: Power-motion transcranial Doppler PMD-TCD is a new method for simultaneous display of flow at multiple depths. We aimed to determine clinical significance of PMD-TCD demonstration of reversed basilar flow in patients with basilar artery (BA) occlusion.
METHODS: We prospectively evaluated patients with acute vertebrobasilar ischemia using PMD-TCD. Using a predefined set of TCD depth criteria and specific flow findings, occlusion was localized to the proximal, middle, or distal BA stem. The National Institutes of Health Stroke Scale was used to measure stroke severity and the modified Rankin Scale (mRS) to assess outcome at 3 months.
RESULTS: BA occlusion was diagnosed in 16 patients (3 women, mean age 65, median NIHSS 8, mean time from symptoms onset 8.5 hours). PMD-TCD diagnosis of BA occlusion was confirmed in 11 of 12 patients who underwent invasive angiography. Reversed BA flow on PMD-TCD was identified in 8 patients (50%). Angiography confirmed flow from carotid system in 6 of these 8 patients (kappa=0.87). Patients with reversed BA flow showed lower NIHSS scores on admission (median 4 versus 15.5, P=0.009), on discharge (2 versus 21.5, P=0.03) and did not experience neurological deterioration during hospital stay (n=0 versus 4, P=0.05). There was a trend toward better outcome at 3 months (mRS 1 versus 4, P=0.07).
CONCLUSIONS: Detection of reversed flow in the distal BA with PMD-TCD is associated with lower stroke severity and better outcome after acute basilar artery occlusion.

Entities:  

Mesh:

Year:  2003        PMID: 14671244     DOI: 10.1161/01.STR.0000106760.25228.2C

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  4 in total

1.  Potential role of PMD-TCD monitoring in the management of hemodynamically unstable intracranial stenosis.

Authors:  Paola Palazzo; Kristian Barlinn; Clotilde Balucani; Limin Zhao; Timothy W Prestley; Andrei V Alexandrov
Journal:  J Neuroimaging       Date:  2010-10-26       Impact factor: 2.486

Review 2.  Usefulness of transcranial Doppler ultrasound in evaluating cervical-cranial collateral circulations.

Authors:  Jingxia Guan; Shaofeng Zhang; Qin Zhou; Chengyan Li; Zuneng Lu
Journal:  Interv Neurol       Date:  2013-10

3.  Duty cycle dependence of ultrasound enhanced thrombolysis in a human clot model.

Authors:  Jason M Meunier; Christy K Holland; Christopher J Lindsell; George J Shaw
Journal:  Ultrasound Med Biol       Date:  2007-04       Impact factor: 2.998

Review 4.  Endovascular management of pediatric high-flow vertebro-vertebral fistula with reversed basilar artery flow. A case report and review of the literature.

Authors:  A R Honarmand; S A Ansari; T D Alden; M Soltanolkotabi; S E Schoeneman; M C Hurley; O Rahman; A Shaibani
Journal:  Interv Neuroradiol       Date:  2013-05-21       Impact factor: 1.610

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.