Macro-/nanoporous silicon as a support for high-performance protein microarrays.

Anton Ressine1, Simon Ekström, György Marko-Varga, Thomas Laurell.   

Abstract

The present work demonstrates the possibilities of using macroporous silicon as a substrate for highly sensitive protein chip applications. The formation of 3D porous silicon structures was performed by electrochemical dissolution of monocrystalline silicon. The fabricated macroporous silicon network has a rigid spongelike structure showing high uniformity and mechanical stability. The microfluidic properties of the substrates were found to be essential for a good bioassay performance. Small spot area, good spot reproducibility, and homogeneous spot profiles were demonstrated on the substrates for immobilized aRIgG. Water contact angles were measured on the porous surface and compared to that of planar silicon, silanized glass, and ordinary microscope glass slides. The effect of the porous surface on the performance of a model IgG-binding immunoassay is presented. aRIgG was microdispensed onto the chip surface forming a microarray of spots with high affinity for the target analyte. The dispensing was performed using an in-house-developed piezoelectric flow-through dispenser. Each spot was formed by a single droplet (100 pL) at each position. The macroporous silicon allowed a high-density microarraying with spot densities up to 4400 spots/cm2 in human plasma samples without cross-talk and consumption of only 0.6 pmol of antibodies/1-cm2 array. Antigen levels down to 70 pM were detected.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14670060     DOI: 10.1021/ac034425q

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Improved porous silicon microarray based prostate specific antigen immunoassay by optimized surface density of the capture antibody.

Authors:  SangWook Lee; Soyoun Kim; Johan Malm; Ok Chan Jeong; Hans Lilja; Thomas Laurell
Journal:  Anal Chim Acta       Date:  2013-07-03       Impact factor: 6.558

2.  Porous silicon antibody microarrays for quantitative analysis: measurement of free and total PSA in clinical plasma samples.

Authors:  Kerstin Järås; Belinda Adler; Axel Tojo; Johan Malm; György Marko-Varga; Hans Lilja; Thomas Laurell
Journal:  Clin Chim Acta       Date:  2012-08-18       Impact factor: 3.786

3.  Integrated acoustic immunoaffinity-capture (IAI) platform for detection of PSA from whole blood samples.

Authors:  A Ahmad Tajudin; K Petersson; A Lenshof; A-M Swärd-Nilsson; L Aberg; G Marko-Varga; J Malm; H Lilja; T Laurell
Journal:  Lab Chip       Date:  2013-05-07       Impact factor: 6.799

Review 4.  Protein microarrays: a chance to study microorganisms?

Authors:  Jürgen Kreutzberger
Journal:  Appl Microbiol Biotechnol       Date:  2006-02-18       Impact factor: 4.813

  4 in total