Literature DB >> 14670045

Ligand-exchange detection of phosphorylated peptides using liquid chromatography electrospray mass spectrometry.

J G Krabbe1, H Lingeman, W M A Niessen, H Irth.   

Abstract

Electrospray ionization mass spectrometry (ESI-MS) is used to selectively detect analytes with a high affinity for metal ions. The detection method is based on the selective monitoring of a competing ligand at its specific m/z value that is released during the ligand-exchange reaction of a metal-ligand complex with analyte(s) eluting from a reversed-phase liquid chromatography column. The ligand-exchange reaction proceeds in a postcolumn reaction detection system placed prior to the inlet of the electrospray MS interface. The feasibility of metal affinity detection by ESI-MS is demonstrated using phosphorylated peptides and iron(III)methylcalcein blue as reactant, as a model system. Methylcalcein blue (MCB) released upon interaction with phosphorylated peptides is detected at m/z 278. The ligand-exchange detection is coupled to a C8 reversed-phase column to separate several nonphosphorylated enkephalins and the phosphorylated peptides pp60 c-src (P) and M2170. Detection limits of 2 microM were obtained for pp60 c-src (P) and M2170. The linearity of the detection method is tested in the range of 2-80 micromol/L phosphorylated compounds (r(2) = 0.9996), and a relative standard deviation of less than 8% (n = 3) for all MCB responses of the different concentrations of phosphorylated compounds was obtained. The presented method showed specificity for phosphorylated peptides and may prove a useful tool for studying other ligand-exchange reactions and metal-protein interactions.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14670045     DOI: 10.1021/ac0349476

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Optimization of post-column reactor radius in capillary high performance liquid chromatography Effect of chromatographic column diameter and particle diameter.

Authors:  Hongjuan Xu; Stephen G Weber
Journal:  J Chromatogr A       Date:  2006-02-21       Impact factor: 4.759

2.  Metal-complex formation in continuous-flow ligand-exchange reactors studied by electrospray mass spectrometry.

Authors:  J G Krabbe; A R de Boer; G van der Zwan; H Lingeman; W M A Niessen; H Irth
Journal:  J Am Soc Mass Spectrom       Date:  2007-01-18       Impact factor: 3.109

Review 3.  Advances in mass spectrometry-based post-column bioaffinity profiling of mixtures.

Authors:  Jeroen Kool; Martin Giera; Hubertus Irth; Wilfried M A Niessen
Journal:  Anal Bioanal Chem       Date:  2010-11-24       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.