Literature DB >> 1466881

Ultrasound beam orientation during standard two-dimensional imaging: assessment by three-dimensional echocardiography.

D L King1, M R Harrison, D L King1, A S Gopal, O L Kwan, A N DeMaria.   

Abstract

Standard two-dimensional echocardiographic image planes are defined by anatomic landmarks and assumptions regarding their orientation when these landmarks are visualized. However, variations of anatomy and technique may invalidate these assumptions and thus limit reproducibility and accuracy of cardiac dimensions recorded from these views. To overcome this problem, we have developed a three-dimensional echocardiograph consisting of a real-time scanner, three-dimensional spatial locater, and personal computer. This system displays the line of intersection of a real-time image and an orthogonal reference image and may be used to assess actual image orientation during standardized two-dimensional imaging when the line-of-intersection display is not observed by the operator. Three hundred forty standard images were assessed from 85 examinations by 11 echocardiographers. Twenty-four percent of the unguided standard images were optimally positioned within +/- 5 mm and +/- 15 degrees of the standard. Of the optimal images, two thirds were parasternal long-axis views. A subsequent study with three-dimensional echocardiography and line-of-intersection guidance of image positioning showed 80% of the guided images to be optimally positioned, a threefold improvement (p < 0.001). Two-dimensional echocardiography does not achieve reasonably consistent optimal positioning of standard imaging views, suggesting that measurements taken from these views are likely to be suboptimal. Three-dimensional echocardiography that uses line-of-intersection guidance improves image positioning threefold and should therefore improve the accuracy and reproducibility of quantitative echocardiographic measurements derived from these images.

Mesh:

Year:  1992        PMID: 1466881     DOI: 10.1016/s0894-7317(14)80322-2

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  12 in total

Review 1.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

2.  Correlation of right ventricular ejection fraction and tricuspid annular plane systolic excursion in tetralogy of Fallot by magnetic resonance imaging.

Authors:  Peter Morcos; G Wesley Vick; David J Sahn; Michael Jerosch-Herold; Alan Shurman; Florence H Sheehan
Journal:  Int J Cardiovasc Imaging       Date:  2008-12-02       Impact factor: 2.357

Review 3.  Simulation for competency assessment in vascular and cardiac ultrasound.

Authors:  Florence H Sheehan; R Eugene Zierler
Journal:  Vasc Med       Date:  2018-02-07       Impact factor: 3.239

4.  Expert consensus for multimodality imaging evaluation of adult patients during and after cancer therapy: a report from the American Society of Echocardiography and the European Association of Cardiovascular Imaging.

Authors:  Juan Carlos Plana; Maurizio Galderisi; Ana Barac; Michael S Ewer; Bonnie Ky; Marielle Scherrer-Crosbie; Javier Ganame; Igal A Sebag; Deborah A Agler; Luigi P Badano; Jose Banchs; Daniela Cardinale; Joseph Carver; Manuel Cerqueira; Jeanne M DeCara; Thor Edvardsen; Scott D Flamm; Thomas Force; Brian P Griffin; Guy Jerusalem; Jennifer E Liu; Andreia Magalhães; Thomas Marwick; Liza Y Sanchez; Rosa Sicari; Hector R Villarraga; Patrizio Lancellotti
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-10       Impact factor: 6.875

Review 5.  Three-dimensional echocardiography: new views from old windows.

Authors:  J R Roelandt
Journal:  Br Heart J       Date:  1995-07

Review 6.  Anatomy of the mitral valve apparatus: role of 2D and 3D echocardiography.

Authors:  Jacob P Dal-Bianco; Robert A Levine
Journal:  Cardiol Clin       Date:  2013-04-15       Impact factor: 2.213

7.  Expert visual guidance of ultrasound for telemedicine.

Authors:  Florence H Sheehan; Michael A Ricci; Cynthia Murtagh; Harry Clark; Edward L Bolson
Journal:  J Telemed Telecare       Date:  2010-02-05       Impact factor: 6.184

8.  Influence of left bundle branch block on left ventricular volumes, ejection fraction and regional wall motion.

Authors:  J A Brunekreeft; M Graauw; P A R de Milliano; J T Keijer
Journal:  Neth Heart J       Date:  2007       Impact factor: 2.380

9.  Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease.

Authors:  Allard T van den Hoven; Jackie S Mc-Ghie; Raluca G Chelu; Anthonie L Duijnhouwer; Vivan J M Baggen; Adriaan Coenen; Wim B Vletter; Marcel L Dijkshoorn; Annemien E van den Bosch; Jolien W Roos-Hesselink
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-19       Impact factor: 2.357

10.  LV function validation of computer-assisted interventional system for cardiac resyncronisation therapy.

Authors:  Maria Panayiotou; R James Housden; Athanasius Ishak; Alexander Brost; Christopher A Rinaldi; Benjamin Sieniewicz; Jonathan M Behar; Tanja Kurzendorfer; Kawal S Rhode
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-30       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.