Literature DB >> 14668505

Ganz reinforcement ring for reconstruction of acetabular defects in revision total hip arthroplasty.

Ariane Gerber1, Markus Pisan, David Zurakowski, Balz Isler.   

Abstract

BACKGROUND: In revision total hip arthroplasty, bone loss due to loosening and migration of the acetabular component makes fixation of a new implant difficult. The purpose of this study was to evaluate the clinical and radiographic outcomes of the use of the Ganz reinforcement ring with nonstructural allograft in the reconstruction of acetabular defects.
METHODS: Sixty-one acetabular revisions performed with use of the Ganz reinforcement ring and nonstructural allograft, between 1989 and 1992, in fifty-seven patients with aseptic loosening met our selection criteria. Eleven hips in eleven patients were lost to follow-up, leaving fifty hips available for evaluation five years or more following surgery. According to the American Academy of Orthopaedic Surgeons classification, twenty-four acetabular defects were Type II, twenty-four were Type III, and two were Type IV. Clinical and radiographic evaluations were carried out at a mean of six and nine years after surgery. Twelve more patients were lost to follow-up before the most recent evaluation.
RESULTS: The mean Merle d'Aubigné composite score increased significantly compared with the preoperative score (p < 0.001). There were seven failures: six cases of aseptic loosening and one case of septic arthritis. Graft incorporation and bone remodeling occurred in all hips but three in which the ring fixation had been inadequate at the time of surgery. The Kaplan-Meier survivorship rate, with use of revision or loosening of the component as the criterion of failure, was 81% at ten years. Inadequate fixation of the implant at the time of surgery was the only multivariate predictor of failure (p = 0.003).
CONCLUSIONS: Patients treated with acetabular revision with a Ganz reinforcement ring had reconstitution of periacetabular bone stock as well as good clinical and radiographic results, provided that the ring had been fixed adequately at the time of surgery. This procedure may not be the preferred approach for reconstructing segmental defects of the medial wall or pelvic discontinuity.

Entities:  

Mesh:

Year:  2003        PMID: 14668505     DOI: 10.2106/00004623-200312000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  27 in total

1.  Large acetabular defects can be managed with cementless revision components.

Authors:  E Scott Paxton; James A Keeney; William J Maloney; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  Long-term results for minor column allografts in revision hip arthroplasty.

Authors:  Paul T H Lee; Guy Raz; Oleg A Safir; David J Backstein; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  [Treatment of acetabular defects with the trabecular metal revision system].

Authors:  G I Wassilew; V Janz; C Perka; M Müller
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

4.  Why revision total hip arthroplasty fails.

Authors:  Bryan D Springer; Thomas K Fehring; William L Griffin; Susan M Odum; John L Masonis
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

5.  The augment-and-modular-cage revision system for reconstruction of severe acetabular defects-two-year clinical and radiographic results.

Authors:  Philip P Roessler; Max Jaenisch; Manuel Kuhlmann; Miriam Wacker; P Johannes Wagenhäuser; Sascha Gravius; Dieter C Wirtz
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

Review 6.  [Comparison of different cup revision systems].

Authors:  K Trieb
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 7.  Acetabular reinforcement rings associated with allograft for severe acetabular defects.

Authors:  Emmanuel Gibon; Luc Kerboull; Jean-Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2018-09-13       Impact factor: 3.075

8.  Outcome of cages in revision arthroplasty of the acetabulum: a systematic review.

Authors:  Alessandro Aprato; Matteo Olivero; Luigi Branca Vergano; Alessandro Massè
Journal:  Acta Biomed       Date:  2019-01-10

9.  [Acetabular revision surgery with the oblong revision cup : clinical and radiological results of 217 cases].

Authors:  S Fickert; S Pfeiffer; A Walter; K P Günther; W-C Witzleb
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

10.  Minimum ten year results of total hip arthroplasty with the acetabular reinforcement ring in avascular osteonecrosis.

Authors:  Peter P Koch; Moritz Tannast; Hiroshi Fujita; Klaus Siebenrock; Reinhold Ganz
Journal:  Int Orthop       Date:  2007-02-15       Impact factor: 3.075