Literature DB >> 14661810

Common-path interferometer for frequency-domain optical coherence tomography.

Andrei B Vakhtin1, Daniel J Kane, William R Wood, Kristen A Peterson.   

Abstract

A Michelson-type spectral interferometer that uses a common beam path for the reference and the sample arms is described. This optical arrangement is more compact and stable than the more commonly used dual-arm interferometer and is well suited for frequency-domain optical coherence tomography of biological samples. With a 16-bit CCD camera, the instrument has sufficient dynamic range and resolution for imaging to depths of 2 mm in scattering biological materials. Images obtained with this spectral interferometer are presented, including cross-sectional images in a Xenopus laevis tadpole.

Entities:  

Mesh:

Year:  2003        PMID: 14661810     DOI: 10.1364/ao.42.006953

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  24 in total

1.  Common-path low-coherence interferometry fiber-optic sensor guided microincision.

Authors:  Kang Zhang; Jin U Kang
Journal:  J Biomed Opt       Date:  2011-09       Impact factor: 3.170

2.  Common path optical coherence tomography with fibre bundle probe.

Authors:  J-H Han; X Liu; C G Song; J U Kang
Journal:  Electron Lett       Date:  2009-10-22       Impact factor: 1.314

3.  Motorized Micro-Forceps with Active Motion Guidance based on Common-Path SSOCT for Epiretinal Membranectomy.

Authors:  Gyeong Woo Cheon; Berk Gonenc; Russell H Taylor; Peter L Gehlbach; Jin U Kang
Journal:  IEEE ASME Trans Mechatron       Date:  2017-09-05       Impact factor: 5.303

4.  Ghost reduction in CP-SSOCT having multiple references using Fourier-domain Shift and Sum.

Authors:  Gyeong Woo Cheon; Peter L Gehlbach; Jin U Kang
Journal:  IEEE Photonics Technol Lett       Date:  2016-06-14       Impact factor: 2.468

5.  Wide-field optical coherence micro-elastography for intraoperative assessment of human breast cancer margins.

Authors:  Wes M Allen; Lixin Chin; Philip Wijesinghe; Rodney W Kirk; Bruce Latham; David D Sampson; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2016-09-19       Impact factor: 3.732

6.  Optical coherence micro-elastography: mechanical-contrast imaging of tissue microstructure.

Authors:  Brendan F Kennedy; Robert A McLaughlin; Kelsey M Kennedy; Lixin Chin; Andrea Curatolo; Alan Tien; Bruce Latham; Christobel M Saunders; David D Sampson
Journal:  Biomed Opt Express       Date:  2014-06-09       Impact factor: 3.732

7.  Common-path phase-sensitive optical coherence tomography provides enhanced phase stability and detection sensitivity for dynamic elastography.

Authors:  Gongpu Lan; Manmohan Singh; Kirill V Larin; Michael D Twa
Journal:  Biomed Opt Express       Date:  2017-10-26       Impact factor: 3.732

8.  Platform for quantitative multiscale imaging of tissue composition.

Authors:  Michael A Pinkert; Zachary J Simmons; Ryan C Niemeier; Bing Dai; Lauren B Woods; Timothy J Hall; Paul J Campagnola; Jeremy D Rogers; Kevin W Eliceiri
Journal:  Biomed Opt Express       Date:  2020-03-12       Impact factor: 3.732

9.  Analysis of multimode fiber bundles for endoscopic spectral-domain optical coherence tomography.

Authors:  Matthew D Risi; Houssine Makhlouf; Andrew R Rouse; Arthur F Gmitro
Journal:  Appl Opt       Date:  2015-01-01       Impact factor: 1.980

10.  A surface topology and motion compensation system for microsurgery guidance and intervention based on common-path optical coherence tomography.

Authors:  Kang Zhang; Weichao Wang; Jaeho Han; Jin U Kang
Journal:  IEEE Trans Biomed Eng       Date:  2009-06-02       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.