Literature DB >> 14657321

Intermittent-mode CT fluoroscopy-guided biopsy of the lung or upper abdomen with breath-hold monitoring and feedback: system development and feasibility.

Stephanie K Carlson1, Joel P Felmlee, Claire E Bender, Richard L Ehman, Kelly L Classic, Houchun H Hu, Tanya L Hoskin.   

Abstract

A bellows-based breath-hold monitoring and feedback system was developed and evaluated for use in intermittent-mode computed tomographic (CT) fluoroscopy-guided biopsy procedures in the lung or upper abdomen. The bellows system is described, and its feasibility is demonstrated in studies with a respiratory phantom and human volunteers. Results are reported for seven patients who underwent bellows-assisted biopsy. Breath-hold monitoring and feedback with the bellows system allow the patient to perform reliable breath holding at a preselected level. This optimizes intermittent-mode CT fluoroscopy-guided biopsies by allowing consistent visualization of the target lesion throughout the procedure.

Entities:  

Mesh:

Year:  2003        PMID: 14657321     DOI: 10.1148/radiol.2293021496

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  A new technique for localization of hepatic tumors that are poorly visible with CT fluoroscopy.

Authors:  Lionel Arrivé; Olivier Rosmorduc; Louisa Azizi; Laurence Monnier-Cholley; Maïté Lewin; Marc Beaussier; Jean-Michel Tubiana
Journal:  Eur Radiol       Date:  2006-04-19       Impact factor: 5.315

2.  Emerging local ablation techniques.

Authors:  Michael J Stone; Bradford J Wood
Journal:  Semin Intervent Radiol       Date:  2006-03       Impact factor: 1.513

3.  Computer tomography guided lung biopsy using interactive breath-hold control: a randomized study.

Authors:  Haseem Ashraf; Shella Krag-Andersen; Matiullah Naqibullah; Valentina Minddal; Annette Nørgaard; Therese Maria Henriette Naur; Peter Sand Myschetzky; Paul Frost Clementsen
Journal:  Ann Transl Med       Date:  2017-06

4.  Effects of flow speed and circulation interval on water quality and zooplankton in a pond-ditch circulation system.

Authors:  Lin Ma; Feng He; Jian Sun; Tao Huang; Dong Xu; Yi Zhang; Zhenbin Wu
Journal:  Environ Sci Pollut Res Int       Date:  2015-02-20       Impact factor: 4.223

5.  Coronary microcirculation changes in non-ischemic dilated cardiomyopathy identified by novel perfusion CT.

Authors:  Wayne L Miller; Thomas R Behrenbeck; Cynthia H McCollough; Eric E Williamson; Shuai Leng; Timothy L Kline; Erik L Ritman
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-25       Impact factor: 2.357

6.  Early changes in myocardial microcirculation in asymptomatic hypercholesterolemic subjects: as detected by perfusion CT.

Authors:  Thomas R Behrenbeck; Cynthia H McCollough; Wayne L Miller; Eric E Williamson; Shuai Leng; Timothy L Kline; Erik L Ritman
Journal:  Ann Biomed Eng       Date:  2014-03       Impact factor: 3.934

7.  Respiratory biofeedback during CT-guided procedures.

Authors:  Julia K Locklin; Jeff Yanof; Alfred Luk; Zoltan Varro; Alexandru Patriciu; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2007-06       Impact factor: 3.464

8.  Using needle orientation sensing as surrogate signal for respiratory motion estimation in percutaneous interventions.

Authors:  Momen Abayazid; Takahisa Kato; Stuart G Silverman; Nobuhiko Hata
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-08-01       Impact factor: 2.924

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.