Literature DB >> 14656583

Flow injection and HPLC determination of furosemide using pulsed amperometric detection at microelectrodes.

Alicia Guzmán1, Lourdes Agüí, María Pedrero, Paloma Yáñez-Sedeño, José M Pingarrón.   

Abstract

The flow-injection and HPLC determination of the diuretic drug furosemide using pulsed amperometric detection (PAD) at cylindrical carbon fibre microelectrodes (CFMEs) is reported. Experimental conditions such as pH (6.5) and buffer concentration (0.05 mol l(-1) HPO4(2-)/H2PO4(-)) were optimized using square-wave voltammetry (SWV). Repetitive flow-injection amperometric measurements at +1.25 V for furosemide showed a continuous decrease in the peak current, probably as a consequence of the microelectrode surface fouling. However, a suitable amperometric detection of furosemide was achieved using a PAD program consisting of a two-step potential waveform with alternating anodic and cathodic polarization. The anodic (detection) potential was +1.25 V (time of application 0.1 s), and the cathodic (cleaning) potential was -0.20 V (t=0.2 s). A linear calibration graph was obtained for furosemide in the 5.0 x 10(-7)-1.0 x 10(-4) mol l(-1) concentration range, with a limit of detection of 1.7 x 10(-7) mol l(-1). HPLC-PAD at carbon fibre microelectrodes was used for the determination of furosemide in the presence of several thiouracil drugs and oxytetracycline (OTC). The mobile phase selected was a 25:75 acetonitrile:5.0 x 10(-3) mol l(-1) NaH2PO4 (pH 5.0) mixture. A linear calibration graph was obtained for furosemide in the 1-100 microM range, with a limit of detection of 0.55 microM. The usefulness of this method for the determination of furosemide in real samples was evaluated by performing the analysis of commercial milk samples spiked with furosemide at a concentration level of 4.5 x 10(-7) mol l(-1) (150 ng ml(-1)), as well as with other thiouracil drugs and OTC. A mean recovery of 95+/-5% furosemide was obtained.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14656583     DOI: 10.1016/s0731-7085(03)00422-9

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  Electrochemically pretreated carbon microfiber electrodes as sensitive HPLC-EC detectors.

Authors:  Zdenka Bartosova; Daniel Riman; Petr Jakubec; Vladimir Halouzka; Jan Hrbac; David Jirovsky
Journal:  ScientificWorldJournal       Date:  2012-04-30

2.  Validated reverse-phase high-performance liquid chromatography for quantification of furosemide in tablets and nanoparticles.

Authors:  Ibrahima Youm; Bi-Botti Celestin Youan
Journal:  J Anal Methods Chem       Date:  2013-09-16       Impact factor: 2.193

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.