Literature DB >> 14653557

Equivalent physical models and formulation of equivalent source layer in high-resolution EEG imaging.

Dezhong Yao1, Bin He.   

Abstract

In high-resolution EEG imaging, both equivalent dipole layer (EDL) and equivalent charge layer (ECL) assumed to be located just above the cortical surface have been proposed as high-resolution imaging modalities or as intermediate steps to estimate the epicortical potential. Presented here are the equivalent physical models of these two equivalent source layers (ESL) which show that the strength of EDL is proportional to the surface potential of the layer when the outside of the layer is filled with an insulator, and that the strength of ECL is the normal current of the layer when the outside is filled with a perfect conductor. Based on these equivalent physical models, closed solutions of ECL and EDL corresponding to a dipole enclosed by a spherical layer are given. These results provide the theoretical basis of ESL applications in high-resolution EEG mapping.

Entities:  

Mesh:

Year:  2003        PMID: 14653557     DOI: 10.1088/0031-9155/48/21/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  REST: a good idea but not the gold standard.

Authors:  Paul L Nunez
Journal:  Clin Neurophysiol       Date:  2010-06-02       Impact factor: 3.708

2.  Is the Surface Potential Integral of a Dipole in a Volume Conductor Always Zero? A Cloud Over the Average Reference of EEG and ERP.

Authors:  Dezhong Yao
Journal:  Brain Topogr       Date:  2017-02-14       Impact factor: 3.020

3.  Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique).

Authors:  Shiang Hu; Dezhong Yao; Pedro A Valdes-Sosa
Journal:  Front Neurosci       Date:  2018-05-03       Impact factor: 4.677

4.  A Comparative Study on the Dynamic EEG Center of Mass with Different References.

Authors:  Yun Qin; Xiuwei Xin; Hao Zhu; Fali Li; Hongchuan Xiong; Tao Zhang; Yongxiu Lai
Journal:  Front Neurosci       Date:  2017-09-12       Impact factor: 4.677

Review 5.  Which Reference Should We Use for EEG and ERP practice?

Authors:  Dezhong Yao; Yun Qin; Shiang Hu; Li Dong; Maria L Bringas Vega; Pedro A Valdés Sosa
Journal:  Brain Topogr       Date:  2019-04-29       Impact factor: 3.020

6.  How Different EEG References Influence Sensor Level Functional Connectivity Graphs.

Authors:  Yunzhi Huang; Junpeng Zhang; Yuan Cui; Gang Yang; Ling He; Qi Liu; Guangfu Yin
Journal:  Front Neurosci       Date:  2017-07-05       Impact factor: 4.677

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.