Medical doctors, who practice interventional cardiology, receive a noticeable radiation dose. In this study, we measured the radiation dose to 9 cardiologists during 144 procedures (72 coronary angiographies and 70 percutaneus translumined coronary angioplasties) in two Greek hospitals. Absorbed doses were measured with TLD placed underneath and over the lead apron at the thyroid protective collar. Based on these measurements, the effective dose was calculated using the Niklason method. In addition, dose area product (DAP) was registered. The effective doses, E, were normalised to the total DAP measured in each procedure, producing the E/DAP index. The mean effective dose values were found to be in the range of 1.2-2.7 microSv while the mean E/DAP values are in the range of 0.010-0.035 microSv/Gycm2. The dependence of dose to the X-ray equipment, the exposure parameters and the technique of the cardiologist were examined. Taking under consideration the laboratories' annual workload, the maximum annual dose was estimated to be 1.9 and 2.8 mSv in the two hospitals.

Entities:  

Mesh:

Year:  2003        PMID: 14652145     DOI: 10.1016/s0720-048x(03)00007-x

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

Review 2.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

3.  Sex proportion of offspring and exposure to radiation in male invasive cardiologists.

Authors:  James W Choi; Praveen Mehrotra; Lee A Macdonald; Lloyd W Klein; Norm M Linsky; Anne M Smith; Mark J Ricciardi
Journal:  Proc (Bayl Univ Med Cent)       Date:  2007-07

4.  Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

Authors:  Uwe Häusler; Renate Czarwinski; Gunnar Brix
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

5.  Age-Dependent Impact of Fluoroscopic Radiation on the Gender of Off-Spring: An International Survey of Cardiologists.

Authors:  Jayasree Pillarisetti; Sowjanya Duthuluru; Hari Sayana; Haley Goucher Goucher; Akshar Patel; Mazda Biria; James Vacek; Loren Berenbom; Sudharani Bommana; Jayan Nath; Mark Wiley; Ajay Nangia; Luigi Di Biase; Andrea Natale; Madhuri Reddy; Buddhadeb Dawn; Dhanunjaya Lakkireddy
Journal:  J Atr Fibrillation       Date:  2013-04-06

6.  Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology.

Authors:  Donald L Miller; Eliseo Vañó; Gabriel Bartal; Stephen Balter; Robert Dixon; Renato Padovani; Beth Schueler; John F Cardella; Thierry de Baère
Journal:  Cardiovasc Intervent Radiol       Date:  2009-12-18       Impact factor: 2.740

7.  The contribution of interventional cardiology procedures to the population radiation dose in a 'health-care level I' representative region.

Authors:  Andrea Peruzzo Cornetto; Stefania Aimonetto; Francesco Pisano; Marcello Giudice; Marco Sicuro; Teodoro Meloni; Santi Tofani
Journal:  Radiat Prot Dosimetry       Date:  2015-05-25       Impact factor: 0.972

8.  Occupational cataracts and lens opacities in interventional cardiology (O'CLOC study): are X-Rays involved? Radiation-induced cataracts and lens opacities.

Authors:  Sophie Jacob; Morgane Michel; Christian Spaulding; Serge Boveda; Olivier Bar; Antoine P Brézin; Maté Streho; Carlo Maccia; Pascale Scanff; Dominique Laurier; Marie-Odile Bernier
Journal:  BMC Public Health       Date:  2010-09-08       Impact factor: 3.295

Review 9.  The biological effects of diagnostic cardiac imaging on chronically exposed physicians: the importance of being non-ionizing.

Authors:  Maria Grazia Andreassi
Journal:  Cardiovasc Ultrasound       Date:  2004-11-22       Impact factor: 2.062

10.  Value of Image Fusion in Coronary Angiography for the Detection of Coronary Artery Bypass Grafts.

Authors:  Julien Plessis; Karine Warin Fresse; Zachary Cahouch; Thibaut Manigold; Vincent Letocart; Laurianne Le Gloan; Béatrice Guyomarch; Patrice Guerin
Journal:  J Am Heart Assoc       Date:  2016-06-10       Impact factor: 5.501

View more