Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds.

E Maria Kristenson1, Peter Korytár, Conny Danielsson, Minna Kallio, Menno Brandt, Jani Mäkelä, René J J Vreuls, Jan Beens, Udo A Th Brinkman.   

Abstract

Different cryogenic and a heated GC x GC modulator(s) were evaluated and compared for the analysis of high-boiling halogenated compounds. The cryogenic modulators investigated were: (i) the longitudinally modulated cryogenic system; (ii) the liquid-nitrogen-cooled jet modulator (KT2001); (iii) a dual-jet CO2 modulator (made in-house); (iv) a semi-rotating cryogenic modulator (made in-house) and (v) a CO2 loop modulator (KT2003); the heated modulator was the slotted heater system (sweeper). Each modulator was optimised with respect to analyte peak widths at half height in the second-dimension. n-Alkanes, chlorinated alkanes, polychlorinated biphenyls (PCBs) and fluorinated polycyclic aromatic hydrocarbons (F-PAHs) were used as test analytes. The flow rate of the coolant was found to be an important parameter, i.e. the flow rate of the gaseous nitrogen in the KT2001, and of the liquid CO2 in the other cryogenic modulators. For the slotted heater the stroke velocity and pause time were important parameters. This modulator had a limited application range in terms of temperature due to a necessary 100 degrees C difference between sweeper and oven temperature. All cryogenic modulators were found to be suitable for the GC x GC analysis of high-boiling compounds, but the CO2 modulators are to be preferred to the KT2001 due to a wider application range and slightly narrower peaks. As regards the performance of three commercially available electron-capture detectors (ECDs), the aim was to obtain narrow peak widths in GC x GC, i.e. to avoid band broadening caused by the cell volume. The most important parameters were the flow rate of the make-up gas and the detector temperature which both should be as high as possible. Comparison of analyte peak widths obtained with ECD mode and flame ionisation detection (FID) showed that all ECDs exhibited band broadening compared to the FID. The narrowest peaks were obtained with the Agilent micro-ECD, which has a cell volume of only 150 microl.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14650605     DOI: 10.1016/s0021-9673(03)01237-8

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Optimizing 2D gas chromatography mass spectrometry for robust tissue, serum and urine metabolite profiling.

Authors:  Zhanru Yu; Honglei Huang; Alexander Reim; Philip D Charles; Alan Northage; Dianne Jackson; Ian Parry; Benedikt M Kessler
Journal:  Talanta       Date:  2017-01-07       Impact factor: 6.057

Review 2.  Recent advances in the application of 2-dimensional gas chromatography with soft and hard ionisation time-of-flight mass spectrometry in environmental analysis.

Authors:  Mohammed S Alam; Roy M Harrison
Journal:  Chem Sci       Date:  2016-04-28       Impact factor: 9.825

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.