Literature DB >> 14649578

Fibrin sealant reduces perioperative blood loss in total hip replacement.

Gwo-Jaw Wang1, Charles A Goldthwaite, Sandra Burks, Ross Crawford, William D Spotnitz.   

Abstract

Patients (n = 81) undergoing total hip replacement (THR) were randomized to receive either standard of care plus fibrin sealant (FS) (10 mL total) or standard of care alone to evaluate the efficacy of FS for reducing blood loss in THR. Considering the 81 intent-to-treat patients, adjusted perioperative blood loss was reduced significantly in the FS group, by 197 mL [95% CI: 45 mL, 319 mL] or 23.5% [95% CI: 5.4%, 38.1%] (p = 0.014). When protocol violators were eliminated, leaving 73 patients, the adjusted FS group perioperative bleeding was reduced by 221 mL [95% CI: 63 mL, 351 mL] or 27.1% [95% CI: 7.6%, 42.5%] (p = 0.0098).

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14649578     DOI: 10.1615/jlongtermeffmedimplants.v13.i5.50

Source DB:  PubMed          Journal:  J Long Term Eff Med Implants        ISSN: 1050-6934


  12 in total

Review 1.  Fibrin sealant (evicel® [quixil®/crosseal™]): a review of its use as supportive treatment for haemostasis in surgery.

Authors:  Sohita Dhillon
Journal:  Drugs       Date:  2011-10-01       Impact factor: 9.546

2.  Use of a fibrin sealant within a blood-saving protocol in patients undergoing revision hip arthroplasty: effects on post-operative blood transfusion and healthcare-related cost analysis.

Authors:  Marco Scardino; Federica Martorelli; Tiziana D'Amato; Giorgia Fenocchio; Vincenzo Simili; Guido Grappiolo; Berardo Di Matteo; Elizaveta Kon; Michele Lagioia
Journal:  Int Orthop       Date:  2019-01-23       Impact factor: 3.075

3.  Prospective randomised evaluation of a collagen/thrombin and autologous platelet haemostatic agent during cementless total hip arthroplasty.

Authors:  David M Joyce; Alison K Klika; Amar Mutnal; Viktor Krebs; Robert Molloy; Ulf Knothe; Wael K Barsoum
Journal:  Blood Transfus       Date:  2015-04-21       Impact factor: 3.443

4.  Tranexamic acid versus fibrin sealant in primary total hip replacement: a comparative study.

Authors:  Aatif Mahmood; Seif Sawalha; Aaron Borbora; Gunasekaran Kumar; Viju Peter
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-01-25

5.  Prevention of postoperative anemia in hip hemiarthroplasty for femoral neck fractures: comparison between local haemostatic agents.

Authors:  Antonio Ziranu; Cesare Meschini; Davide De Marco; Giuseppe Sircana; Maria Serena Oliva; Giusepp Rovere; Andrea Corbingi; Raffaele Vitiello; Giulio Maccauro; Enrico Pola
Journal:  Orthop Rev (Pavia)       Date:  2022-10-13

6.  Blood loss reduction in cementless total hip replacement with fibrin spray or bipolar sealer: a randomised controlled trial on ninety five patients.

Authors:  Francesco Falez; Antonio Meo; Gabriele Panegrossi; Fabio Favetti; Filippo La Cava; Filippo Casella
Journal:  Int Orthop       Date:  2013-05-18       Impact factor: 3.075

Review 7.  Fibrin sealant use for minimising peri-operative allogeneic blood transfusion.

Authors:  P A Carless; D A Henry; D M Anthony
Journal:  Cochrane Database Syst Rev       Date:  2003

8.  Reduction of blood loss in primary hip arthroplasty with tranexamic acid or fibrin spray.

Authors:  Jamie S McConnell; Sandeep Shewale; Niall A Munro; Kalpesh Shah; Angela H Deakin; Andrew W G Kinninmonth
Journal:  Acta Orthop       Date:  2011-10-17       Impact factor: 3.717

Review 9.  Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive-a Laboratory and Clinical Perspective.

Authors:  William D Spotnitz
Journal:  ISRN Surg       Date:  2014-03-04

10.  Saline-coupled bipolar sealing in simultaneous bilateral total knee arthroplasty.

Authors:  Atul F Kamath; Daniel C Austin; Peter B Derman; R Carter Clement; Jonathan P Garino; Gwo-Chin Lee
Journal:  Clin Orthop Surg       Date:  2014-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.