Literature DB >> 1464844

Estimating the strength of common input to human motoneurons from the cross-correlogram.

M A Nordstrom1, A J Fuglevand, R M Enoka.   

Abstract

1. The relationship between the motor unit discharge pattern (rate and variability) and synchronization of motor unit pairs was studied in the first dorsal interosseus muscle of human subjects. In separate trials of up to 4 min duration, subjects voluntarily controlled the mean discharge rate of an identified motor unit at one of several prescribed rates (range 7.5-17.5 Hz). 2. The effect of discharge rate on the synchronous peak in the cross-correlogram was examined in eighty motor unit pairs from six subjects. Five commonly used synchronization indices were used to quantify synchrony in the cross-correlograms constructed from different discharge-rate trials. For each synchronization index, the apparent magnitude of synchrony increased at lower motor unit discharge rates. The synchronization indices were not equally sensitive to discharge rate; increases in the different indices ranged from 72 to 494% between the highest and lowest discharge rates. 3. A model of the membrane potential trajectory underlying rhythmic motoneuron discharge was used to explain the observed increase in the magnitude of the synchronization indices at lower discharge rates. The essential feature of this model is that the probability of a common-input EPSP causing a synchronous discharge in two motoneurons is independent of discharge rate. This means that the number of synchronous action potentials in excess of chance in any trial depends on the properties of the common-input EPSPs and the duration of the trial, but is not related to motor unit discharge rates. The model also demonstrated that when the excess synchronous counts are normalized to motor unit discharge rate, or baseline counts in the histogram (as in the conventional synchronization indices), the magnitude of the index increases when the motor unit discharge rates are low. 4. The strength of common input to motoneurons could be misinterpreted if conventional synchronization indices are used because of discharge-rate effects. The model was used to derive an index of the strength of common input to motoneurons (CIS) that was independent of motor unit discharge rate. CIS is the frequency of synchronous action potentials in the motor unit pair in excess of those expected due to chance (calculated during periods of tonic discharge in both units). The mean CIS in first dorsal interosseus motor unit pairs ranged from 0.052 to 1.005 extra synchronous action potentials per second across subjects. 5. Discharge variability was correlated with each of the synchronization indices and the CIS.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1464844      PMCID: PMC1175573          DOI: 10.1113/jphysiol.1992.sp019244

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  28 in total

1.  Synchronization of motor units in human masseter during a prolonged isometric contraction.

Authors:  M A Nordstrom; T S Miles; K S Türker
Journal:  J Physiol       Date:  1990-07       Impact factor: 5.182

Review 2.  Generation of spike trains in CNS neurons.

Authors:  W H Calvin
Journal:  Brain Res       Date:  1975-01-24       Impact factor: 3.252

3.  Variation in the degree of synchronization exhibited by motor units lying in different finger muscles in man.

Authors:  F D Bremner; J R Baker; J A Stephens
Journal:  J Physiol       Date:  1991-01       Impact factor: 5.182

4.  Correlation between the discharges of motor units recorded from the same and from different finger muscles in man.

Authors:  F D Bremner; J R Baker; J A Stephens
Journal:  J Physiol       Date:  1991-01       Impact factor: 5.182

5.  Characteristics of postsynaptic potentials produced in single human motoneurons by homonymous group 1 volleys.

Authors:  P Ashby; D Zilm
Journal:  Exp Brain Res       Date:  1982       Impact factor: 1.972

6.  Cumulative sum technique and its application to the analysis of peristimulus time histograms.

Authors:  P H Ellaway
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1978-08

7.  Short-term synchronization of intercostal motoneurone activity.

Authors:  T A Sears; D Stagg
Journal:  J Physiol       Date:  1976-12       Impact factor: 5.182

8.  Central nervous pathways underlying synchronization of human motor unit firing studied during voluntary contractions.

Authors:  A K Datta; S F Farmer; J A Stephens
Journal:  J Physiol       Date:  1991-01       Impact factor: 5.182

9.  Relation between shapes of post-synaptic potentials and changes in firing probability of cat motoneurones.

Authors:  E E Fetz; B Gustafsson
Journal:  J Physiol       Date:  1983-08       Impact factor: 5.182

10.  The synaptic connexions to intercostal motoneurones as revealed by the average common excitation potential.

Authors:  P A Kirkwood; T A Sears
Journal:  J Physiol       Date:  1978-02       Impact factor: 5.182

View more
  82 in total

1.  Motor unit synchronisation is enhanced during slow lengthening contractions of a hand muscle.

Authors:  John G Semmler; Kurt W Kornatz; Devin V Dinenno; Shi Zhou; Roger M Enoka
Journal:  J Physiol       Date:  2002-12-01       Impact factor: 5.182

2.  Recruitment of motor units in two fascicles of the semispinalis cervicis muscle.

Authors:  Jochen Schomacher; Jakob Lund Dideriksen; Dario Farina; Deborah Falla
Journal:  J Neurophysiol       Date:  2012-03-07       Impact factor: 2.714

3.  Properties of human motor units after prolonged activity at a constant firing rate.

Authors:  K V B Johnson; S C Edwards; C Van Tongeren; P Bawa
Journal:  Exp Brain Res       Date:  2003-10-22       Impact factor: 1.972

4.  Optimization of input patterns and neuronal properties to evoke motor neuron synchronization.

Authors:  Anna M Taylor; Roger M Enoka
Journal:  J Comput Neurosci       Date:  2004 Mar-Apr       Impact factor: 1.621

5.  Responses of single motor units in human masseter to transcranial magnetic stimulation of either hemisphere.

Authors:  Sophie L Pearce; Timothy S Miles; Philip D Thompson; Michael A Nordstrom
Journal:  J Physiol       Date:  2003-04-11       Impact factor: 5.182

6.  Motor unit recruitment strategies and muscle properties determine the influence of synaptic noise on force steadiness.

Authors:  Jakob L Dideriksen; Francesco Negro; Roger M Enoka; Dario Farina
Journal:  J Neurophysiol       Date:  2012-03-14       Impact factor: 2.714

Review 7.  Mechanical properties and neural control of human hand motor units.

Authors:  Andrew J Fuglevand
Journal:  J Physiol       Date:  2011-10-17       Impact factor: 5.182

8.  Synchronization of motor unit firings: an epiphenomenon of firing rate characteristics not common inputs.

Authors:  Joshua C Kline; Carlo J De Luca
Journal:  J Neurophysiol       Date:  2015-10-21       Impact factor: 2.714

9.  Periodic modulation of motor-unit activity in extrinsic hand muscles during multidigit grasping.

Authors:  Jamie A Johnston; Sara A Winges; Marco Santello
Journal:  J Neurophysiol       Date:  2005-03-02       Impact factor: 2.714

10.  Frequency-dependent synaptic depression modifies postsynaptic firing probability in cats.

Authors:  B D Clark; T C Cope
Journal:  J Physiol       Date:  1998-10-01       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.