Literature DB >> 14644717

Clear lens extraction for the correction of high myopia.

Luis Fernández-Vega1, José F Alfonso, Tomás Villacampa.   

Abstract

OBJECTIVE: To evaluate the postoperative outcomes and intraoperative and postoperative complications of clear lens extraction (CLE) with posterior chamber intraocular lens (IOL) implantation in highly myopic eyes.
DESIGN: Retrospective case series. PARTICIPANTS: One hundred seven patients (190 eyes) who had undergone CLE with posterior chamber IOL implantation and who had been observed for at least 3 years after surgery.
METHODS: Medical records of patients who had undergone CLE with posterior chamber IOL implantation to treat high myopia (axial length >26.00 mm) over 7 years (January 1990 to December 1996) were reviewed. Visual acuity and refractive error were assessed before and after surgery, and perioperative, intraoperative, and postoperative complications were recorded. MAIN OUTCOME MEASURES: Axial length, preoperative and final best spectacle-corrected visual acuity (BSCVA), preoperative and postoperative spherical equivalent (SE), argon laser treatments, surgical complications, neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy, retinal detachment (RD), time from surgery or Nd:YAG capsulotomy to RD, subfoveal choroidal neovascularization (CNV), and follow-up period.
RESULTS: The mean postoperative follow-up period was 4.78 years (range, 3.10-8.03 years). Final BSCVA was better than preoperative BSCVA in 159 eyes (83.68%), equal in 24 eyes (12.63%), and worse in 7 eyes (3.68%). Postoperative BSCVA was 20/40 or better in 136 eyes (71.60%) vs. 52 eyes (27.36%) before surgery (P<0.001). The mean final postoperative SE was -1.22 diopters. The risk of Nd:YAG laser capsulotomy was 77.89%. The incidence of RD was 2.10%; retinal reattachment was achieved in all cases, and none of these eyes had worse final BSCVA than before surgery. Subfoveal CNV developed in 4 eyes (2.10%) of 3 patients; all of these eyes presented with a macular lacquer crack.
CONCLUSIONS: Clear lens extraction with posterior chamber IOL implantation has good outcomes with acceptable predictability and improvement in best-corrected visual acuity. During follow-up, patients tended to remain stable, and the risk of retinal detachment was low. We attribute our favorable results to careful patient selection and follow-up.

Entities:  

Mesh:

Year:  2003        PMID: 14644717     DOI: 10.1016/S0161-6420(03)00794-2

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  22 in total

1.  Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation.

Authors:  José F Alfonso; Luis Fernández-Vega; Susana Ortí; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-16       Impact factor: 3.117

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Choroidal neovascularization in highly myopic eyes after cataract surgery.

Authors:  Kengo Hayashi; Kyoko Ohno-Matsui; Soh Futagami; Seiji Ohno; Takashi Tokoro; Manabu Mochizuki
Journal:  Jpn J Ophthalmol       Date:  2006 Jul-Aug       Impact factor: 2.447

Review 5.  [Complications after refractive lens exchange].

Authors:  D Kook; A Kampik; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

6.  Vincenz Fukala (1847-1911) and the early history of clear-lens operations in high myopia.

Authors:  Dieter Schmidt; Andrzej Grzybowski
Journal:  Saudi J Ophthalmol       Date:  2012-12-06

7.  Correction of high myopia with different phakic anterior chamber intraocular lenses: ICARE angle-supported lens and Verisyse iris-claw lens.

Authors:  Stanislawa Gierek-Ciaciura; Ariadna Gierek-Lapinska; Krzysztof Ochalik; Ewa Mrukwa-Kominek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07-01       Impact factor: 3.117

Review 8.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

9.  Choroidal neovascular membrane following clear lens extraction.

Authors:  Banu Turgut Oztürk; Hürkan Kerimoğlu; Umit Kamış; Saban Gönül; Süleyman Okudan
Journal:  Clin Ophthalmol       Date:  2007-12

10.  Assessment of phacoaspiration techniques in clear lens extraction for correction of high myopia.

Authors:  Mostafa A El-Helw; Ahmed M Emarah
Journal:  Clin Ophthalmol       Date:  2010-03-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.