Literature DB >> 14643214

Applications of a bilateral denoising filter in biological electron microscopy.

Wen Jiang1, Matthew L Baker, Qiu Wu, Chandrajit Bajaj, Wah Chiu.   

Abstract

Due to the sensitivity of biological sample to the radiation damage, the low dose imaging conditions used for electron microscopy result in extremely noisy images. The processes of digitization, image alignment, and 3D reconstruction also introduce additional sources of noise in the final 3D structure. In this paper, we investigate the effectiveness of a bilateral denoising filter in various biological electron microscopy applications. In contrast to the conventional low pass filters, which inevitably smooth out both noise and structural features simultaneously, we found that bilateral filter holds a distinct advantage in being capable of effectively suppressing noise without blurring the high resolution details. In as much, we have applied this technique to individual micrographs, entire 3D reconstructions, segmented proteins, and tomographic reconstructions.

Entities:  

Mesh:

Year:  2003        PMID: 14643214     DOI: 10.1016/j.jsb.2003.09.028

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  37 in total

1.  Structural studies of Hantaan virus.

Authors:  Anthony J Battisti; Yong-Kyu Chu; Paul R Chipman; Bärbel Kaufmann; Colleen B Jonsson; Michael G Rossmann
Journal:  J Virol       Date:  2010-11-10       Impact factor: 5.103

2.  Removing Contamination-Induced Reconstruction Artifacts from Cryo-electron Tomograms.

Authors:  Jose-Jesus Fernandez; Ulrike Laugks; Miroslava Schaffer; Felix J B Bäuerlein; Maryam Khoshouei; Wolfgang Baumeister; Vladan Lucic
Journal:  Biophys J       Date:  2015-12-30       Impact factor: 4.033

3.  Modeling Cardiovascular Anatomy from Patient-Specific Imaging Data.

Authors:  Chandrajit Bajaj; Samrat Goswami
Journal:  Comput Methods Appl Sci       Date:  2009-01-01

4.  RSV capsid polymorphism correlates with polymerization efficiency and envelope glycoprotein content: implications that nucleation controls morphogenesis.

Authors:  Carmen Butan; Dennis C Winkler; J Bernard Heymann; Rebecca C Craven; Alasdair C Steven
Journal:  J Mol Biol       Date:  2007-12-08       Impact factor: 5.469

5.  Rotavirus architecture at subnanometer resolution.

Authors:  Zongli Li; Matthew L Baker; Wen Jiang; Mary K Estes; B V Venkataram Prasad
Journal:  J Virol       Date:  2008-11-26       Impact factor: 5.103

6.  Electron tomography, three-dimensional Fourier analysis and colour prediction of a three-dimensional amorphous biophotonic nanostructure.

Authors:  Matthew D Shawkey; Vinodkumar Saranathan; Hildur Pálsdóttir; John Crum; Mark H Ellisman; Manfred Auer; Richard O Prum
Journal:  J R Soc Interface       Date:  2009-01-20       Impact factor: 4.118

7.  Evaluation of denoising algorithms for biological electron tomography.

Authors:  Rajesh Narasimha; Iman Aganj; Adam E Bennett; Mario J Borgnia; Daniel Zabransky; Guillermo Sapiro; Steven W McLaughlin; Jacqueline L S Milne; Sriram Subramaniam
Journal:  J Struct Biol       Date:  2008-04-22       Impact factor: 2.867

8.  Multiscale geometric modeling of macromolecules I: Cartesian representation.

Authors:  Kelin Xia; Xin Feng; Zhan Chen; Yiying Tong; Guo Wei Wei
Journal:  J Comput Phys       Date:  2014-01       Impact factor: 3.553

9.  A validated active contour method driven by parabolic arc model for detection and segmentation of mitochondria.

Authors:  Serdar F Tasel; Erkan U Mumcuoglu; Reza Z Hassanpour; Guy Perkins
Journal:  J Struct Biol       Date:  2016-03-05       Impact factor: 2.867

10.  Developing a denoising filter for electron microscopy and tomography data in the cloud.

Authors:  Zbigniew Starosolski; Marek Szczepanski; Manuel Wahle; Mirabela Rusu; Willy Wriggers
Journal:  Biophys Rev       Date:  2012-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.