Literature DB >> 14641426

Incidence of rotary ProFile instrument fracture and the potential for bypassing in vivo.

K S Al-Fouzan1.   

Abstract

AIM: To determine the incidence of rotary ProFile instrument fracture and the potential for bypassing in molar teeth in vivo.
METHODOLOGY: Four hundred and nineteen maxillary and mandibular first and second molars (1457 canals) were cleaned and shaped by two endodontists with new and used sets of nickel-titanium ProFile.04 taper rotary instruments. Each set of instruments was used in five molars and was steam-autoclaved before use. The canals were instrumented using passive instrumentation and a crown-down preparation technique. Instruments were examined both before and after use to evaluate whether breakage or deformation had occurred. All canals were instrumented to at least a size 30 at the working length.
RESULTS: Nineteen instruments demonstrated visible signs of plastic deformation and were discarded and replaced, whilst 21 instruments underwent intracanal fracture during treatment. Amongst these, 14 fractured in the apical third, whilst the remaining seven fractured in the middle third. Seven instruments were bypassed, and treatment was completed. There was a significantly greater number of instrument fractures with the size 20 ProFile than with the other sizes, especially after the second time of use (P < 0.05).
CONCLUSIONS: Prolonged clinical use of ProFile nickel-titanium instruments increased their fracture rate. One-third of fractured instruments were bypassed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14641426     DOI: 10.1111/j.1365-2591.2003.00733.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  8 in total

1.  The incidence of nickel-titanium endodontic hand file fractures: A 7-year retrospective study in a tertiary care hospital.

Authors:  Arun Kumar Patnana; Ankita Chugh; Vinay Kumar Chugh; Pravin Kumar
Journal:  J Conserv Dent       Date:  2020-10-10

2.  Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.

Authors:  Pallavi Reddy Y; Kavita S; C V Subbarao
Journal:  J Clin Diagn Res       Date:  2014-02-03

3.  The Impact of Three Different Canal Lubricants on Fracture, Deformity and Metal Slivering of ProTaper Rotary Instruments.

Authors:  Yazdan Shantiaee; Omid Dianat; Farnoud Sharifi; Golnaz Nahvi; Golbarg Kolahi Ahari
Journal:  Iran Endod J       Date:  2014-03-08

4.  Apical Microleakage in Root Canals Containing Broken Rotary Instruments.

Authors:  Mostafa Godiny; Reza Hatam; Atefeh Khavid; Shahryar Khanlari
Journal:  Iran Endod J       Date:  2017

5.  Success Rate and Time for Bypassing the Fractured Segments of Four NiTi Rotary Instruments.

Authors:  Alireza Adl; Arash Shahravan; Melika Farshad; Shahab Honar
Journal:  Iran Endod J       Date:  2017

6.  The top 10 most-cited articles on the management of fractured instruments: a bibliometric analysis.

Authors:  Lora Mishra; Hyeon-Cheol Kim; Naomi Ranjan Singh; Priti Pragati Rath
Journal:  Restor Dent Endod       Date:  2018-12-26

7.  Incidence of fracture of ProDesign Logic system instruments: A cross-sectional retrospective study.

Authors:  Ricardo Machado; Claudemir de Souza Júnior; Bruna Larissa Mendes; Viviane Vieira; Stella Maria Glaci Reinke; Ana Cristina Gonçalves Kovalik; Eduardo Donato Eing Elgelke Back; Daniel Comparin
Journal:  Sci Rep       Date:  2022-05-12       Impact factor: 4.996

8.  Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System-An In Vitro Study.

Authors:  Vicente Faus-Matoses; Eva Burgos Ibáñez; Vicente Faus-Llácer; Celia Ruiz-Sánchez; Álvaro Zubizarreta-Macho; Ignacio Faus-Matoses
Journal:  Int J Environ Res Public Health       Date:  2022-01-10       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.