Literature DB >> 1464131

Measuring recovery from general anaesthesia using critical flicker frequency: a comparison of two methods.

Y Salib1, G Plourde, K Alloul, A Provost, A Moore.   

Abstract

Critical flicker frequency (CFF) is the frequency at which a flickering light appears steady. It is a sensitive measure for assessing recovery from anaesthesia. The CFF is almost always determined with the method of limits by which the flickering frequency is progressively decreased (or increased) until the patient reports a change from fusion to flicker (or flicker to fusion). This method has two disadvantages: it is influenced by the response bias (i.e., the subjective criterion used by the subject to decide that flicker is present or absent) and by the response delay (i.e., the interval between the perceptual change and the response). To avoid these problems, the method of forced choice is recommended. For each trial, the subject observes the light during two short successive periods. The light flickers during only one period, according to chance. The patient must indicate the period during which flickers occur. If uncertain, the patient has to make a guess. The aim of this study was to compare the two methods for assessing recovery from general anaesthesia. Two induction agents were used to obtain different recovery profiles. Twenty patients undergoing uncomplicated surgery lasting less than two hours were tested. They received either thiopentone or midazolam for induction, according to a randomized design. Vecuronium was used to facilitate tracheal intubation and anaesthesia was maintained with fentanyl, isoflurane and nitrous oxide. The CFF was measured before induction and at 60, 120 and 180 minutes after arrival in the recovery room. The person measuring CFF was unaware of the induction agent used.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1464131     DOI: 10.1007/BF03008373

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  9 in total

Review 1.  The assessment of postoperative mental function.

Authors:  G B Drummond
Journal:  Br J Anaesth       Date:  1975-02       Impact factor: 9.166

2.  THE MEASUREMENT OF RECOVERY FROM ANAESTHESIA.

Authors:  M D VICKERS
Journal:  Br J Anaesth       Date:  1965-05       Impact factor: 9.166

3.  Flicker fusion frequency; background and applications.

Authors:  E SIMONSON; J BROZEK
Journal:  Physiol Rev       Date:  1952-07       Impact factor: 37.312

4.  Critical flicker frequency (CFF) and psychotropic drugs in normal human subjects-a review.

Authors:  J M Smith; H Misiak
Journal:  Psychopharmacologia       Date:  1976-05-28

5.  An evaluation of tests of psychomotor function in assessing recovery following a brief anaesthetic.

Authors:  J N Cashman; S J Power
Journal:  Acta Anaesthesiol Scand       Date:  1989-11       Impact factor: 2.105

6.  Psychomotor recovery after three methods of sedation during spinal anaesthesia.

Authors:  I G Kestin; P B Harvey; C Nixon
Journal:  Br J Anaesth       Date:  1990-06       Impact factor: 9.166

Review 7.  Psychomotor function and psychoactive drugs.

Authors:  I Hindmarch
Journal:  Br J Clin Pharmacol       Date:  1980-09       Impact factor: 4.335

8.  Midazolam compared with thiopentone as a hypnotic component in balanced anaesthesia: a randomized, double-blind study.

Authors:  J G Reves; R Vinik; A M Hirschfield; C Holcomb; S Strong
Journal:  Can Anaesth Soc J       Date:  1979-01

9.  Sedation during spinal anaesthesia: comparison of propofol and midazolam.

Authors:  E Wilson; A David; N MacKenzie; I S Grant
Journal:  Br J Anaesth       Date:  1990-01       Impact factor: 9.166

  9 in total
  4 in total

1.  Heart rate variability and critical flicker fusion frequency changes during and after parachute jumping in experienced skydivers.

Authors:  M Cavalade; V Papadopoulou; S Theunissen; C Balestra
Journal:  Eur J Appl Physiol       Date:  2015-02-26       Impact factor: 3.078

2.  Persistence of critical flicker fusion frequency impairment after a 33 mfw SCUBA dive: evidence of prolonged nitrogen narcosis?

Authors:  C Balestra; P Lafère; P Germonpré
Journal:  Eur J Appl Physiol       Date:  2012-04-03       Impact factor: 3.078

3.  Sedation with midazolam during regional anaesthesia: is there a role for flumazenil?

Authors:  L Claffey; G Plourde; J Morris; M Trahan; D M Dean
Journal:  Can J Anaesth       Date:  1994-11       Impact factor: 5.063

4.  Evaluation of Critical Flicker-Fusion Frequency Measurement Methods for the Investigation of Visual Temporal Resolution.

Authors:  Auria Eisen-Enosh; Nairouz Farah; Zvia Burgansky-Eliash; Uri Polat; Yossi Mandel
Journal:  Sci Rep       Date:  2017-11-15       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.