Abstract

This paper reports in situ noninvasive blood glucose monitoring by use of near-infrared (NIR) diffuse-reflectance spectroscopy. The NIR spectra of the human forearm were measured in vivo by using a pair of source and detector optical fibers separated by a distance of 0.65 mm on the skin surface. This optical geometry enables the selective measurement of dermis tissue spectra due to the skin's optical properties and reduces the interference noise arising from the stratum corneum. Oral glucose intake experiments were performed with six subjects (including a single subject with type I diabetes) whose NIR skin spectra were measured at the forearm. Partial least-squares regression (PLSR) analysis was carried out and calibration equations were obtained with each subject individually. Without exception among the six subjects, the regression coefficient vectors of their calibration models were similar to each other and had a positive peak at around 1600 nm, corresponding to the characteristic absorption peak of glucose. This result indicates that there is every possibility of glucose detection in skin tissue using our measurement system. We also found that there was a good correlation between the optically predicted values and the directly measured values of blood samples with individual subjects. The potential of noninvasive blood glucose monitoring using our methodology was demonstrated by the present study.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14639751     DOI: 10.1366/000370203769699090

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  14 in total

1.  Wavelet analysis used for spectral background removal in the determination of glucose from near-infrared single-beam spectra.

Authors:  Boyong Wan; Gary W Small
Journal:  Anal Chim Acta       Date:  2010-09-22       Impact factor: 6.558

2.  Iris as a reflector for differential absorption low-coherence interferometry to measure glucose level in the anterior chamber.

Authors:  Yong Zhou; Nan Zeng; Yanhong Ji; Yao Li; Xiangsong Dai; Peng Li; Lian Duan; Hui Ma; Yonghong He
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

3.  Multifunctional materials for implantable and wearable photonic healthcare devices.

Authors:  Geon-Hui Lee; Hanul Moon; Hyemin Kim; Gae Hwang Lee; Woosung Kwon; Seunghyup Yoo; David Myung; Seok Hyun Yun; Zhenan Bao; Sei Kwang Hahn
Journal:  Nat Rev Mater       Date:  2020-01-07       Impact factor: 66.308

4.  Noninvasive in vivo glucose sensing on human subjects using mid-infrared light.

Authors:  Sabbir Liakat; Kevin A Bors; Laura Xu; Callie M Woods; Jessica Doyle; Claire F Gmachl
Journal:  Biomed Opt Express       Date:  2014-06-23       Impact factor: 3.732

5.  Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements.

Authors:  Narahara Chari Dingari; Ishan Barman; Gajendra P Singh; Jeon Woong Kang; Ramachandra R Dasari; Michael S Feld
Journal:  Anal Bioanal Chem       Date:  2011-04-21       Impact factor: 4.142

6.  Noninvasive glucose detection in human skin using wavelength modulated differential laser photothermal radiometry.

Authors:  Xinxin Guo; Andreas Mandelis; Bernard Zinman
Journal:  Biomed Opt Express       Date:  2012-10-29       Impact factor: 3.732

7.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection.

Authors:  Jonas Kottmann; Julien M Rey; Joachim Luginbühl; Ernst Reichmann; Markus W Sigrist
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

8.  In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light.

Authors:  Sabbir Liakat; Kevin A Bors; Tzu-Yung Huang; Anna P M Michel; Eric Zanghi; Claire F Gmachl
Journal:  Biomed Opt Express       Date:  2013-06-11       Impact factor: 3.732

Review 9.  Recent advances in application of biosensors in tissue engineering.

Authors:  Anwarul Hasan; Md Nurunnabi; Mahboob Morshed; Arghya Paul; Alessandro Polini; Tapas Kuila; Moustafa Al Hariri; Yong-kyu Lee; Ayad A Jaffa
Journal:  Biomed Res Int       Date:  2014-08-06       Impact factor: 3.411

10.  Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents.

Authors:  Takehiro Yamakoshi; Jihyoung Lee; Kenta Matsumura; Yasuhiro Yamakoshi; Peter Rolfe; Daiki Kiyohara; Ken-ichi Yamakoshi
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.