Literature DB >> 14639136

Reliability of pharmacodynamic analysis by logistic regression: mixed-effects modeling.

Wei Lu1, James G Ramsay, James M Bailey.   

Abstract

BACKGROUND: Many pharmacologic studies record data as binary, yes-or-no, variables with analysis using logistic regression. In a previous study, it was shown that estimates of C50, the drug concentration associated with a 50% probability of drug effect, were unbiased, whereas estimates of gamma, the term describing the steepness of the concentration-effect relationship, were biased when sparse data were naively pooled for analysis. In this study, it was determined whether mixed-effects analysis improved the accuracy of parameter estimation.
METHODS: Pharmacodynamic studies with binary, yes-or-no, responses were simulated and analyzed with NONMEM. The bias and coefficient of variation of C50 and gamma estimates were determined as a function of numbers of patients in the simulated study, the number of simulated data points per patient, and the "true" value of gamma. In addition, 100 sparse binary human data sets were generated from an evaluation of midazolam for postoperative sedation of adult patients undergoing cardiac surgery by random selection of a single data point (sedation score vs. midazolam plasma concentration) from each of the 30 patients in the study. C50 and gamma were estimated for each of these data sets by using NONMEM and were compared with the estimates from the complete data set of 656 observations.
RESULTS: Estimates of C50 were unbiased, even for sparse data (one data point per patient) with coefficients of variation of 30-50%. Estimates of gamma were highly biased for sparse data for all values of gamma greater than 1, and the value of gamma was overestimated. Unbiased estimation of gamma required 10 data points per patient. The coefficient of variation of gamma estimates was greater than that of the C50 estimates. Clinical data for sedation with midazolam confirmed the simulation results, showing an overestimate of gamma with sparse data.
CONCLUSION: Although accurate estimations of C50 from sparse binary data are possible, estimates of gamma are biased. Data with 10 or more observations per patient is necessary for accurate estimations of gamma.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14639136     DOI: 10.1097/00000542-200312000-00005

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  8 in total

1.  The effective bolus dose of remifentanil to facilitate laryngeal mask airway insertion during inhalation induction of sevoflurane in children.

Authors:  Hyuckgoo Kim; Sung Mee Jung; Sang-Jin Park
Journal:  J Anesth       Date:  2015-03-26       Impact factor: 2.078

2.  Effective dose of nefopam in 80% of patients (ED80): a study using the continual reassessment method.

Authors:  Hélène Beloeil; Mathilde Eurin; Aude Thévenin; Dan Benhamou; Jean-Xavier Mazoit
Journal:  Br J Clin Pharmacol       Date:  2007-06-19       Impact factor: 4.335

3.  A pharmacodynamic analysis of factors affecting recovery from anesthesia with propofol-remifentanil target controlled infusion.

Authors:  Bon-Nyeo Koo; Jeong-Rim Lee; Gyu-Jeong Noh; Jae-Hoon Lee; Young-Ran Kang; Dong-Woo Han
Journal:  Acta Pharmacol Sin       Date:  2012-07-30       Impact factor: 6.150

4.  Modeling of recovery profiles in mentally disabled and intact patients after sevoflurane anesthesia; a pharmacodynamic analysis.

Authors:  Teo Jeon Shin; Gyu-Jeong Noh; Yong-Seo Koo; Dong Woo Han
Journal:  Yonsei Med J       Date:  2014-11       Impact factor: 2.759

5.  A Simulation Study of Propofol Effect-Site Concentration for Appropriate Sedation in Pediatric Patients Undergoing Brain MRI: Pharmacodynamic Analysis.

Authors:  Se Hee Na; Young Song; So Yeon Kim; Hyo Jin Byon; Hwan Ho Jung; Dong Woo Han
Journal:  Yonsei Med J       Date:  2017-11       Impact factor: 2.759

6.  Population Pharmacodynamic Modeling Using the Sigmoid Emax Model: Influence of Inter-individual Variability on the Steepness of the Concentration-Effect Relationship. a Simulation Study.

Authors:  Johannes H Proost; Douglas J Eleveld; Michel M R F Struys
Journal:  AAPS J       Date:  2020-12-24       Impact factor: 4.009

7.  Gender Affects the Median Effective Dose and 95% Effective Dose of Oxycodone for Blunting the Hemodynamic Response to Tracheal Intubation in Narcotic-Naïve Adult Patients.

Authors:  Xian-Hui Kang; Fang-Ping Bao; Hong-Gang Zhang; Dan-Jun Yu; Ke Ha; Qing Xie; Sheng-Mei Zhu
Journal:  Chin Med J (Engl)       Date:  2018-08-20       Impact factor: 2.628

8.  Current clinical methods of measurement of respiratory rate give imprecise values.

Authors:  Gordon B Drummond; Darius Fischer; D K Arvind
Journal:  ERJ Open Res       Date:  2020-09-28
  8 in total